AEMC 514
Catalog #: 2117.70
Clamp-on Meter (AC/DC, TRMS, 1000AAC/DC, 750VAC/1000VDC, Hz, Ohms, Continuity)
- Overview
- Specifications
- Summary
- Temp. Probes
- Accessories
Product Highlights
- Resistance measurements to 4000Ω
- Continuity with beeper below 40Ω
- Frequency measurements from V and A
- Diode test
- 1ms Peak function for fast capture of signals
- Standard size, full function clamp-on meters
- 1000AAC or 1000AAC/DC current measurements
- Ideal for inrush measurement
- Hold function to “freeze” readings
- 750VAC or 1000VDC volt measurements
- TRMS measurements (Models 512 and 514)
- Push-button for easy ADC zeroing
- Large, easy-to-read 4000-count display
- 42-segment analog bargraph
- Supplied with test leads and soft carrying pouch
Applications
- Commercial, industrial, residential and HVAC troubleshooting
- Power panel, junction box and battery bank monitoring
- AC or DC motor testing
- Power plant troubleshooting
- Electrical testing and troubleshooting on traditional and non-linear loads, such as adjustable speed drives and computers
Each Unit Includes
- Test Leads
- Soft Carrying Pouch
| AC Current |
| Range |
0.05A to 1000A |
| Resolution |
40A: 0.01A; 400A: 0.1A; 1000A: 1A |
| Basic Accuracy |
50 to 60Hz: ±1.9% of Reading + 5cts; 60 to 500Hz: ±2.5% of Reading + 5cts |
| Frequency Range |
50 to 500Hz |
| Overload Protection |
40A: 1200Arms; 400A: 1200Arms; 1000A: 1200Arms |
| DC Amperes |
| Range |
1A to 1000A |
| Resolution |
40A: 0.01A, 400A: 0.1A; 1000A: 1A |
| Accuracy |
±2.5% of Reading + 10cts |
| Overload Protection |
1200Arms |
| AC Volts |
| Input Range |
0.5V to 750V |
| Range |
400V / 750V |
| Resolution |
0.1V / 1V |
| Accuracy |
±1.5% of Reading + 5cts |
| Input Impedance |
10MW |
| Overload Protection |
1000Vrms |
| Frequency Current Input |
| Range |
4kHz |
| Resolution |
1Hz |
| Minimum Input Signal |
2Arms |
| Accuracy |
±0.1% of Reading + 1ct |
| Frequency Voltage Input |
| Range |
10kHz |
| Resolution |
10Hz |
| Minimum Input Signal |
5Vrms |
| Accuracy |
±0.1% of Reading + 1ct |
| DC Volts |
| Range |
0.2 to 1000V |
| Resolution |
400V: 0.1V; 1000V: 1V |
| Accuracy |
±1% of Reading + 2cts |
| Input Impedance |
10MW |
| Overload Protection |
1200Vrms |
| Continuity |
| Range |
Beeper |
| Measurement |
<40W |
| Max. Test Voltage |
3VDC |
| Overload Protection |
600Vrms |
| General Specifications |
| Digital Display |
Digital: 3¾ digits LCD display, 4000 count (max. reading 3999) |
| Analog Display |
Fast 42-segment analog bargraph display |
| Symbol & Scale Range |
Automatic according to range and input signal |
| Polarity |
Minus sign displayed when negative signal applied to input |
| Overload |
OL Displayed when input signal exceeds range |
| Sample Rate |
2 samples/sec for the digital display; 20 samples/sec for the analog bargraph |
| Jaw Opening Size |
1.575" (40mm) |
| Battery |
9V, NEDA 1604 or 6F22 or 006P |
| Low Battery Indicator |
Symbol displayed when the battery is below the required voltage |
| Auto Power Off |
The meter will power itself OFF if there is no push button or rotary switch operation for 30 minutes |
| Dimensions |
9.53 x 2.60 x 1.42" (242 x 66 x 36mm) |
| Weight |
14.10oz (400g) with batteries |
| Environmental Specification |
| Operating Temperature |
32° to 104°F (0° to 40°C), <80% RH, non-condensing |
| Storage Temperature |
14° to 140°F (-10° to 60°C), <70% RH, battery removed |
| Operating Altitude |
2167 ft (2000m) |
| Safety / Reference Specifications |
Safety / Reference Specifications |
| Protection Level |
Double insulation; EN 61010, 600V, Cat. III and EN 61010, 1000V, Cat. II |
| Agency Approvals |
CE Mark |
| Clamp Meters/Clamp Meters Template |
| Type |
Standard Style |
| True RMS |
Yes |
| Maximum Current AC |
1000 A |
| Minimum Current AC |
0.05 mA |
| Maximum Current DC |
1000 A |
| Minimum Current DC |
1 A (1000 mA) |
| Maximum Voltage AC |
750 V |
| Minimum Voltage AC |
0.1 V (100 mV) |
| Maximum Voltage DC |
1000 V |
| Minimum Voltage DC |
0.1 V (100 mV) |
| Basic Voltage Accuracy |
1.2% of reading ± 5cts |
| Digits Display |
3.75 |
| Resolution AC Volts |
0.1 V |
| Resolution DC Volts |
0.1 V |
| Resolution AC Current |
0.1 A |
| Resolution DC Current |
0.1 A |
| Maximum Conductor Size |
1.575 IN |
| Auto Ranging/Manual |
Auto Ranging |
| Auto Power Off |
Yes |
| Detachable Jaw |
No |
| Rotating Jaw / Swivel |
No |
| Peak Hold |
Yes |
| Min/Max |
Yes |
| In-Rush Current |
No |
| Dual Display |
No |
| Analog Bargraph on Display |
Yes |
| Backlight |
No |
| Remote Display |
No |
| Resistance |
Yes |
| Frequency |
Yes |
| Continuity |
Yes |
| Capacitance |
No |
| Temperature (K T/C) |
Yes |
| Temperature (IR Sensor) |
No |
| Diode Testing |
Yes |
| CAT Rating |
IV |
| CAT Voltage |
1,000 V, 300 V, 600 V |
| Overload Protector |
Yes |
| True Power (KW) |
No |
| Apparent Power (VA) |
No |
| Power Factor (PF) |
No |
| Single Phase/Three Phase |
Single Phase |
| Crest Factor |
No |
| Energy (KWh) |
No |
| Reactive Power (KVAR) |
No |
| Source/Simulate (Process Clamp) |
No |
| Data Logging |
No |
| Warranty |
12 MONTHS (1 YEARS) |
| Calibration Included |
Factory Calibration |
| Power Supply Voltage |
Battery Powered |
| Safety Approval |
CE |
| Product Weight |
14.1 OUNCES (0.881 LBS) |
| Battery Type |
9v |
| Product Height |
1.42 IN |
| Product Length |
9.53 IN |
| Product Width |
2.6 IN |
| Shipping Weight |
4 LBS |
| ECCN Number |
EAR99 |
| HTS/Schedule B Number |
9039310000 |
| Country of Origin |
Taiwan |
| UPC |
685338110067 |
|
Temp. Probes
Accessories
| Product |
Price |
 |
AEMC 2152.05
Catalog #: 2152.05
Lead - Set of 2, Color-coded (Red/Black) Silicone Leads, Test Probes & Alligator Clips {Rated 1000V CAT IV} (Replacement for Models 401, 403, 405, 407, 601, 603, 605, 607, F05 & F09)
|
$0.00
|
 |
AEMC 2154.74
Catalog #: 2154.74
Lead - Replacement Set of 2, Needle Tip Color-coded (Red/Black) w/4mm Right-angle Plug {600V Cat IV w/shield on Needle Tip, 1000V CAT II w/o Sheild} for Models 5212-5217 (or any meter that accepts 4mm banana plugs)
|
$12.21
|
|
|
|