| Frequency Range: 40 to 10kHz Limit Operating Conditions: 200A permanently to 1kHz; Derating above 3kHz: 200A x (1/0.333 F), F in kHz Common Mode Voltage: 600VAC Crest Factor: 3 @10Arms with an error (due to CF) of 3% Current Overload: 240A for 10 min Reference Conditions: 20° to 26°C, 20 to 75% RH, 48 to 65Hz, external magnetic field 40A/m, 48 to 65Hz sine wave, distortion factor less than 1%, no DC component, no external current carrying conductor, test sample centered. Load impedance 1MW Working Voltage: 600VAC Altitude: Operating: 0 to 2000m; Non-operating: 0 to 12km Colors: Dark gray handles with red cover Dimensions: 5.47 x 2.00 x 1.18" (139 x 51 x 30mm) Drop Test: Test per IEC 68-2-32: 1.0 m drop on 38 mm of Oak on concrete Jaw Opening: .84" (21mm) Material: Jaws: Polycarbonate with 10% fiberglass charge, Red UL 94 V0; Case: Polycarbonate Maximum Bus Bar Size: 0.78 x 0.19" (20 x 5mm) Maximum Cable Diameter: One 0.78" & Oslash; (20mm) Mechanical Shock: 100g per IEC 68-2-27 Operating Temperature: 14° to 131°F (-10° to 55°C) Operating Relative Humidity: 10° to 35°C 85% RH (without roll-off above 35°C) Output: Two standard safety banana jacks (4mm) Protection Index (IP): IP 40 (IEC 529) Impact Test: IK04 0.5 J EN50102 Storage Temperature: -40° to 158°F (-40° to 70°C) Vibration: Test per IEC 68-2-6 Weight: 6.5 oz (180g) Influence of Temperature: £150 ppm/°K, or 0.15% of mV output per 10K° |