AEMC 2620
Catalog #: 2125.52
Leakage Current Probe Model 2620 (4A, 1V/A and 400A, 1mV/A output)
- Overview
- Specifications
- Summary
Product Highlights
- Very high sensitivity
- Differential or leakage current from 500μA
- Current up to 400A
- Two switch-selectable measurement ranges: 4AAC/400AAC
- Large inside jaw diameter (>4") allows use on large or multiple conductors
- Work with single-, dual- and three-phase networks
- Connect directly to DMMs on mV or VAC range
| ELECTRICAL - 4A Range |
| Current Range |
500μA to 4A |
| Output Signal |
1mV/mA (4V max) |
| Accuracy |
500μA to 10mA - 3% of Reading ± 1mV
10mA to 100mA - 0.5% of Reading ± 0.5mV
100mA to 4A - 0.5% of Reading ± 0.5mV |
| Phase Shift |
10mA to 100mA - <15°
100mA to 4A - <10° |
| Load Impedance (DMM) |
1MΩ min |
| Frequency Range |
48 to 1000Hz |
| Output Termination |
5 ft (1.5m) Lead with 4mm safety banana plugs |
| MECHANICAL |
| Dimensions |
11.22 x 6.89 x 1.77" (285 x 175 x 45mm) |
| Jaw Opening |
4.4" (112mm) |
| Maximum Conductor Size |
4.4" (112mm) |
| Weight |
2.87 lbs (1300g) |
| ENVIRONMENTAL |
| Operating Temperature |
-14° to 131°F (-10° to 55°C); 0 to 85% RH (non-condensing) |
| Storage Temperature |
-40° to 158°F (-40° to 70°C); 0 to 85% RH (non-condensing) |
| SAFETY |
| Safety Rating |
EN 61010-2-032, 600V Cat. III |
| Double Insulation |
Yes |
| CE Mark |
Yes |
| Clamp Meters/Current Clamp Adaptors / Current Clamps Template |
| CAT Rating |
III |
| CAT Voltage Rating (V) |
600V |
| Data Logging |
No |
| Unique Features |
Differential of leakage current from 500 Micro-amps.
4.4" jaw opening |
| Warranty |
12 MONTHS (1 YEARS) |
| Calibration Included |
Factory Calibration |
| Product Weight |
2.87 LBS |
| Shipping Weight |
6 LBS |
| ECCN Number |
EAR99 |
| Country of Origin |
France |
|
|
|
|