AEMC 565
Catalog #: 2117.56
Clamp-on Leakage Current Meter (TRMS, 60mA, 600mA, 10A, 100A, 600VAC/DC, Hz, Ohms, Continuity)
- Overview
- Specifications
- Summary
- Temp. Probes
- Accessories
Product Highlights
- Check for leakage and locate insulation breakdowns on live circuits.
- Measures leakage current up to 600mA with up to 10μA resolution.
- Measures current up to 100Arms
- Measures up to 600Vac/dc
- Measures Hz on either V or A inputs
- Measures Resistance and Continuity
- Hold feature freezes Value
- Max feature keeps track of highest measured In-rush value
- Zero button ideal for measuring relative values
- Filter to isolate 50/60Hz fundamental from harmonics
- Compatible with VDE 0404
- The Model 565 includes two color-coded test leads, soft carrying case and user manual.
Applications:
- Ground fault current measurement
- Electrical safety compliance testing
- Medical device safety testing
- Process loop monitoring
- General AC load monitoring
- Industrial troubleshooting checks
mA AC Current (TRMS, Auto-Ranging) |
Measurement Range |
0 to 600mA |
Resolution 60mA
600mA |
0.01mA (10μA)
0.1mA (100μA) |
Accuracy 50 to 60Hz
50 to 500Hz
500Hz to 3kHz |
1.2% of Reading ± 5cts
2.5% of Reading ± 5cts
3.5% of Reading ± 10cts |
AC Current (TRMS, Auto-Ranging) |
Measurement Range |
10 to 100A |
Resolution 10A
100A |
0.001A (1mA)
0.01A (10mA) |
Accuracy 50 to 60Hz
50 to 500Hz
500Hz to 3kHz |
1.2% of Reading ± 5cts
2.5% of Reading ± 5cts
3.5% of Reading ± 10cts |
AC Voltage (TRMS) |
Measurement Range |
0 to 600V |
Resolution |
0.1V |
Accuracy 50 to 60Hz
50 to 500Hz
500Hz to 3kHz |
1.0% of Reading ± 5cts
1.2% of Reading ± 5cts
2.5% of Reading ± 10cts |
DC Voltage |
Measurement Range |
0 to 600V |
Resolution |
0.1V |
Accuracy |
1.0% of Reading ± 3cts |
Frequency (Auto-Ranging) |
Function |
A-Hz | V-Hz |
Resolution 0 to 100Hz
100Hz to 1kHz |
0.1Hz | 0.1Hz
1Hz | 1Hz |
Sensitivity |
10mArms min | 5Vrms min |
Accuracy |
0.5% of Reading ± 2cts |
Resistance |
Measurement Range |
0 to 1kΩ |
Resolution |
0.1Ω |
Accuracy |
1.0% of Reading ± 3cts |
Continuity |
Measurement Range |
0 to 1kΩ |
Resolution |
0.1Ω |
Buzzer |
<35Ω ±25Ω |
Overload Protection |
660Vrms/150Arms |
Nominal Sample Rate |
Two measurements per second (approx.) |
MAX Sample Rate |
100ms |
Filter |
On (50/60Hz only); Off (Full frequency range) |
In-Rush |
Max 100ms sample time |
Power Source |
Two 1.5V AAA batteries |
Battery Life |
45 hrs (approx.) |
Power-Off |
10 min approx with user override |
Low Battery Indication |
is displayed when battery voltage is low |
MECHANICAL |
Dimensions |
8.5 x 2.5 x 1.18" (218 x 64 x 30mm) |
Jaw Opening |
1.10" (28mm) |
Maximum Conductor Size |
1" (26mm) |
Weight |
10 oz (280g) with batteries |
DISPLAY |
Display Type |
Four digit LCD |
Backlight |
LED with 180 sec Auto-Off |
ENVIRONMENTAL |
Operating Temperature |
32° to 104°F (0° to 40°C); <80% RH (non-condensing) |
Storage Temperature |
14° to 140°F (-10° to 60°C); <70% RH (non-condensing) |
SAFETY |
Safety Rating |
EN 61010-1 Ed. 2001, EN 61010-2-032 Ed. 2003, 600V, Cat. III |
Double Insulation |
Yes |
CE Mark |
Yes |
Clamp Meters/Clamp Meters Template |
Type |
Current Leakage Clamp |
True RMS |
Yes |
Maximum Current AC |
100 A |
Minimum Current AC |
0.01 mA |
Maximum Voltage AC |
600 V |
Minimum Voltage AC |
0.0 mV |
Maximum Voltage DC |
600 V |
Minimum Voltage DC |
0.1 V (100 mV) |
Basic Voltage Accuracy |
2.5% of reading ±5cts |
Digits Display |
3.75 |
Resolution AC Volts |
0.0 V |
Resolution AC Current |
0.01 mA (0.00001 A) |
Maximum Conductor Size |
1.10 IN |
Auto Ranging/Manual |
Auto Ranging |
Auto Power Off |
Yes |
Detachable Jaw |
No |
Rotating Jaw / Swivel |
No |
Peak Hold |
No |
Min/Max |
No |
In-Rush Current |
No |
Dual Display |
No |
Analog Bargraph on Display |
No |
Backlight |
Yes |
Remote Display |
No |
Resistance |
Yes |
Frequency |
No |
Continuity |
Yes |
Capacitance |
No |
Temperature (K T/C) |
No |
Temperature (IR Sensor) |
No |
Diode Testing |
No |
CAT Rating |
III |
Overload Protector |
Yes |
True Power (KW) |
No |
Apparent Power (VA) |
No |
Power Factor (PF) |
No |
Single Phase/Three Phase |
Single Phase |
Crest Factor |
No |
Energy (KWh) |
No |
Reactive Power (KVAR) |
No |
Source/Simulate (Process Clamp) |
No |
Data Logging |
No |
Warranty |
12 MONTHS (1 YEARS) |
Calibration Included |
Factory Calibration |
Power Supply Voltage |
Battery Powered |
Safety Approval |
CE |
Product Weight |
10 OUNCES (0.625 LBS) |
Battery Type |
AAA |
Product Height |
1.8 IN |
Product Length |
8.5 IN |
Product Width |
2.5 IN |
Shipping Weight |
3 LBS |
ECCN Number |
EAR99 |
HTS/Schedule B Number |
9039310000 |
Country of Origin |
Taiwan |
UPC |
685338110166 |
|
Temp. Probes
Accessories
Product |
Price |
|
AEMC 2152.05
Catalog #: 2152.05
Lead - Set of 2, Color-coded (Red/Black) Silicone Leads, Test Probes & Alligator Clips {Rated 1000V CAT IV} (Replacement for Models 401, 403, 405, 407, 601, 603, 605, 607, F05 & F09)
|
$0.00
|
|
AEMC 2154.74
Catalog #: 2154.74
Lead - Replacement Set of 2, Needle Tip Color-coded (Red/Black) w/4mm Right-angle Plug {600V Cat IV w/shield on Needle Tip, 1000V CAT II w/o Sheild} for Models 5212-5217 (or any meter that accepts 4mm banana plugs)
|
$12.21
|
|
|
|