|
|
Fluke 1587 FC
Catalog #: 4691215
2-in-1 Insulation Multimeter with Fluke Connect
- Overview
- Specifications
- Summary
- Accessories
- Cases
- Current Clamps
- Temp. Probes
- DMM Probe Kits
Product Highlights
- Large display with backlight
- Insulation test: 0.01 MΩ to 2 GΩ
- Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V
- Live circuit detection prevents insulation test if voltage >30 V is detected
- Auto-discharge of capacitive voltage
- AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance, Continuity
- Filter for motor drive measurements
- Capacitance, diode test, temperature, Min/Max, frequency
- Auto power off to save battery power
- CAT III 1000 V, CAT IV 600 V measurement category
- 3-Year warranty
Fluke Connect Features:
- Fluke Connect allows you to wirelessly transfer data from your existing Fluke tools to your smart phone
- Fits over the IR port of your existing Fluke tools
- Upgradeable by USB
- Immediately enables you to graph, save, and share the tool’s readings with your team from your smart phone
Supported smart phones:
- Android™ 4.3 & up
- iPhone® 4s & later
Each Unit Includes
- Remote probe
- Test leads
- Alligator clips
- K-type thermocouple
- Hard case
- User documentation
GENERAL SPECIFICATIONS |
Maximum voltage applied to any terminal and common |
1000 V |
Storage temperature |
-40 °C to 60 °C (-40 °F to 140 °F) |
Operating temperature |
-20 °C to 55 °C (-4 °F to 131 °F) |
Temperature coefficient |
0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F) |
Relative humidity |
Noncondensing |
0 % to 95 % @ 10 °C to 30 °C |
(50 °F to 86 °F) |
0 % to 75 % @ 30 °C to 40 °C |
(86 °F to 104 °F) |
0 % to 40 % @ 40 °C to 55 °C |
(104 °F to 131 °F) |
Vibration |
Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument |
Radio frequency communication |
2.4 GHz ISM Band |
Radio frequency certification |
FCC: T68-FBLE, IC: 6627A-FBLE |
Electromagnetic compatibility |
International IEC 61326-1 |
Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A : Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected. |
Korea (KCC) |
Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. |
USA (FCC) |
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Enclosure protection |
IEC 60529: IP40 (non-operating) |
Safety |
IEC 61010-1 |
Pollution Degree 2 |
IEC 61010-2-033 |
CAT IV 600 V/CAT III 1000 V |
Batteries |
Four AA batteries (NEDA 15A or IEC LR6) |
Battery life |
Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MO with a duty cycle of 5 seconds on and 25 seconds off. |
Size |
5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) |
Weight |
550 g (1.2 lb) |
Altitude |
Operating |
2000 m |
Storage |
12,000 m |
Over-Range capability |
110 % of range except for capacitance which is 100 % |
Frequency overload protection |
<107 V-Hz |
Fuse Protection for mA input |
0.44A, 1000 V, IR 10 kA |
ELECTRICAL SPECIFICATIONS |
AC voltage measurement |
Accuracy (1587 FC only) |
Range |
Resolution |
50 Hz to 60 Hz ± (% of Rdg + counts) |
60 Hz to 5000 Hz ± (% of Rdg + counts) |
600.0 mV |
0.1 mV |
± (1 % + 3) |
± (2 % + 3) |
6.000 V |
0.001 V |
± (1 % + 3) |
± (2 % + 3) |
60.00 V |
0.01 V |
± (1 % + 3) |
± (2 % + 3) |
600.0 V |
0.1 V |
± (1 % + 3) |
± (2 % + 3) 1 |
1000 V |
1 V |
± (2 % + 3) |
± (2 % + 3) 1 |
1 1 kHz bandwidth |
Low-Pass Filter Voltage (1587 FC only) |
Range |
Resolution |
50 Hz to 60 Hz ± (% of Rdg + Counts) |
60 Hz to 400 Hz ± (% of Rdg + Counts) |
600.0 mV |
0.1 mV |
± (1 % + 3) |
+ (2 % + 3) - (6 % - 3) |
6.000 V |
0.001 V |
± (1 % + 3) |
+ (2 % + 3) - (6 % - 3) |
60.00 V |
0.01 V |
± (1 % + 3) |
+ (2 % + 3) - (6 % - 3) |
600.0 V |
0.1 V |
± (1 % + 3) |
+ (2 % + 3) - (6 % - 3) |
1000 V |
1 V |
± (2 % + 3) |
+ (2 % + 3) - (6 % - 3) |
1577 accuracy |
Range |
Resolution |
50 Hz to 60 Hz ± (% of Rdg + Counts) |
600.0 mV |
0.1 mV |
± (2 % + 3) |
6.000 V |
0.001 V |
± (2 % + 3) |
60.00 V |
0.01 V |
± (2 % + 3) |
600.0 V |
0.1 V |
± (2 % + 3) |
1000 V |
1 V |
± (2 % + 3) |
AC Conversion |
Inputs are ac coupled true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 up to 500 V, decreasing linearly to a crest factor =1.5 at 1000 V. For non-sinusoidal waveforms add ± (2 % reading + 2 % FS) typical, for a crest factor up to 3. |
Input Impedance |
10 MΩ (nominal), <100 pF, ac-coupled |
Common mode rejection ratio (1 kΩ unbalanced) |
>60 dB at dc, 50 or 60 Hz |
DC voltage measurement |
Range |
Resolution |
Accuracy 1587 FC1
± (% of Rdg + Counts) |
Accuracy 15771
± (% of Rdg + Counts) |
6.000 V dc |
0.001 V |
± (0.09 % + 2) |
± (0.2 % + 2) |
60.00 V dc |
0.01 V |
± (0.09 % + 2) |
± (0.2 % + 2) |
600.0 V dc |
0.1 V |
± (0.09 % + 2) |
± (0.2 % + 2) |
1000 V dc |
1 V |
± (0.09 % + 2) |
± (0.2 % + 2) |
1 Accuracies apply to ± 100% of range. |
Input Impedance: 10 MΩ (nominal), <100 pF |
Normal mode rejection ratio: >60 dB @ 50 Hz or 60 Hz |
Common mode rejection ratio: >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalanced) |
DC millivolts measurement |
Range |
Resolution |
Accuracy 1587 FC ± (% of Rdg + Counts) |
Accuracy 1577 ± (% of Rdg + Counts) |
600.0 mV dc |
0.1 mV |
± (0.1 % + 1) |
± (0.2 % + 1) |
DC and AC current measurement |
Range |
Resolution |
Accuracy 1587 FC ± (% of Rdg+Counts) |
Accuracy 1577 ± (% of Rdg+Counts) |
Burden voltage (Typical) |
AC 45 Hz to 1000 Hz |
400 mA |
0.1 mA |
± (1.5 % + 2) 1 |
± (2 % + 2) 1 |
2 mV/mA |
60 mA |
0.01 mA |
± (1.5 % + 2) 1 |
± (2 % + 2) 1 |
|
DC |
400 mA |
0.1 mA |
± (0.2 % + 2) |
± (1.0 % + 2) |
2 mV/mA |
60 mA |
0.01 mA |
± (0.2 % + 2) |
± (1.0 % + 2) |
|
1 1 kHz bandwidth |
Overload: 600 mA for 2 minutes maximum |
Fuse protection for mA Input: 0.44 mA, 1000 V, IR 10 kA |
AC conversion: Inputs are ac coupled true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor =1.5 at 600 mA. For non-sinusoidal waveforms add +(2 % reading + 2 % FS) typical, for a crest factor up to 3. |
Ohms measurement |
Range |
Resolution |
Accuracy 1587 FC1
+ (% of Rdg+Counts) |
Accuracy 15771
+ (% of Rdg+Counts) |
600.0 Ω |
0.1 Ω |
± (0.9 % + 2) |
± (1.2 % + 2) |
6.000 kΩ |
0.001 kΩ |
60.00 kΩ |
0.01 kΩ |
600.0 kΩ |
0.1 KΩ |
6.000 MΩ |
0.001 MΩ |
50.0 MΩ [2] |
0.01 MΩ |
± (1.5 % + 3) |
± (2.0 % + 3) |
1 Accuracies apply from 0 % to 100 % of range. 2 Up to 80 % relative humidity. |
Overload protection: 1000 V rms or dc |
Open circuit test voltage: <8.0 V dc |
Short circuit current: <1.1 mA |
Diode test (1587 FC only) |
Diode test indication |
Display voltage drop: 0.6 V at 1.0 mA nominal test current |
Accuracy |
± (2 % + 3) |
Continuity test |
Continuity indication |
Continuous audible tone for test resistance below 25 O and off above 100 O. Maximum reading; 1000 O |
Open circuit voltage |
<8.0 V |
Short circuit current |
1.0 mA typical |
Overload protection |
1000 V rms |
Response time |
>1 m sec |
Frequency measurement (1587 FC only) |
Range |
Resolution |
Accuracy ± (% of Rdg+Counts) |
99.99 Hz |
0.01 Hz |
± (0.1 % + 1) |
999.9 Hz |
0.1 Hz |
± (0.1 % + 1) |
9.999 kHz |
0.001 kHz |
± (0.1 % + 1) |
99.99kHz |
0.01 kHz |
± (0.1 % + 1) |
Frequency counter sensitivity |
Input range |
V ac Sensitivity (RMS Sine Wave)1 |
DC trigger levels to 20 kHz2 |
5 Hz to 20 kHz |
20 kHz to 100 kHz |
|
600.0 mV ac |
100.0 mV |
150.0 mV |
NA |
6.0 V |
1.0 V |
1.5 V |
-400.0 mV and 2.5 V |
60.0 V |
10.0 V |
36.0 V |
1.2 V and 4.0 V |
600.0 V |
100.0 V |
|
12.0 V and 40.0 V |
1000.0 V |
300.0 V |
|
12.0 V and 40.0 V |
1 Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy. |
2 Usable to 100 kHz with full scale input. |
Capacitance (1587 FC only) |
Range |
Resolution |
Accuracy ± (% of Rdg+Counts) |
1000 nF |
1 nF |
± (1.2 % + 2) |
10.00 µF |
0.01 µF |
100.0 µF |
0.1 µF |
± (1.2 % + 90 counts) |
9999 µF |
1 µF |
Temperature measurement (1587 FC only) |
Range |
Resolution |
Accuracy 1 ± (% of Rdg+Counts) |
-40 ° C to 537 ° C |
0.1 °C |
± (1 % + 10 counts) |
-40 ° F to 998 ° F |
0.1 °F |
± (1 % + 18 counts) |
1 Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument. |
INSULATION SPECIFICATIONS |
Measurement range |
Model 1587 FC: 0.01 MΩ to 2 GΩ
Model 1577: 0.1 MΩ to 600 MΩ |
Test voltages |
Model 1587 FC: 50, 100, 250, 500, 1000 V
Model 1577: 500, 1000 V |
Test voltage accuracy |
+20 %, -0 % |
Short-Circuit test current |
1 mA nominal |
Auto discharge |
Discharge time <0.5 second for C = 1 µF or less |
Live circuit detection |
Inhibit test if terminal voltage > 30 V prior to initialization of test |
Maximum capacitive load |
Operable with up to 1 µF load |
Multimeters Template |
Type |
Digital |
Style |
Hand-Held |
Measures AC V |
Yes |
Measures DC V |
Yes |
Measures AC A |
Yes |
Measures DC A |
Yes |
True RMS |
Yes |
Maximum Voltage AC |
1000 V |
Minimum Voltage AC |
0 V (0 mV) |
Resolution AC Volts |
0.1 V (100 mV) |
Maximum Voltage DC |
1000 V |
Minimum Voltage DC |
0 V (0 mV) |
Resolution DC Volts |
0.001 V (1 mV) |
Maximum Current AC |
400 mA (0.4 A) |
Minimum Current AC |
1 mA |
Resolution AC Current |
0.01 mA |
Maximum Current DC |
400 mA (0.4 A) |
Minimum Current DC |
1 mA |
Resolution DC Current |
0.01 mA |
Basic Accuracy V DC |
±(0.09%+2) |
# Digit Display |
3.75 |
Counts |
6000 . |
Backlight |
Yes |
Manual/Autoranging |
Both |
Dual Display |
Yes |
Analog Bargraph on Display |
No |
Decibels |
No |
Resistance |
Yes |
Frequency |
Yes |
Continuity |
Yes |
Capacitance |
Yes |
Temperature |
Yes |
Diode Testing |
Yes |
CAT Rating |
IV |
CAT Voltage |
1,000 V, 600 V |
Intrinsically Safe |
No |
Peak Hold |
Yes |
Overload Protector |
Yes |
Kelvin 4-Wire Measurement Capability |
No |
Wireless Display |
No |
Data Hold |
Yes |
Low-Pass Filter |
Yes |
Micro / Milli / Meg Ohmmeters/Megohmmeter / Insulation Resistance Testers Template |
IR Test Voltage |
1,000 V, 100 V, 250 V, 50 V, 500 V |
Maximum Insulation Resistance |
2 G Ohms |
Minimum Insulation Resistance |
0.01 M Ohms (0.00001 G Ohms) |
Variable Incremental Voltage |
No |
Display (Megohmmeter) |
Digital |
Continuity Test |
Yes |
Live Circuit Voltage Detection |
Yes |
Power Supply |
Battery |
Timer |
No |
Unique Features |
Insulation test voltages 50V, 100V, 250V, 500V, 1000V
Insulation test: 0.01 MΩ to 2.0 GΩ
Auto discharge of capacitive voltage
Insulation test smoothing reading
Frequency
Capacitance
Diode test
Temperature
Min/Max
Low pass filter (for work on VSD's)
AC/DC Voltage
DC millivolts
AC/DC milliamps |
Warranty |
3 YEARS |
Calibration Included |
None |
Power Supply Voltage |
Battery Powered |
Safety Approval |
CSA |
Data Logging |
No |
IP Rating |
IP40 |
Product Weight |
4.72 LBS |
Battery Type |
AA |
Product Height |
7.99 IN |
Product Length |
3.97 IN |
Product Width |
7.96 IN |
Shipping Weight |
5.19 LBS |
Country of Origin |
United States |
Shipping Height |
7.99 IN |
Shipping Length |
3.97 IN |
Shipping Width |
7.96 IN |
UPC |
095969262958 |
|
Accessories
Cases
Current Clamps
Temp. Probes
DMM Probe Kits
|
|
|