Fluke 714B
Catalog #: 4387869
Thermocouple Temperature Calibrator
- Overview
- Specifications
- Summary
- Temp. Probes
- Accessories
Product Highlights
- The 714B can measure and simulate (17) different thermocouple types and millivolts
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Hanging tool designed in and included with every unit
- Configurable 0% and 100% source settings for quick 25% linearity checks
- Linear ramp and 25% step auto ramp based on 0% and 100% settings
- Dual inputs and backlit display for easy interpretation of measurements
- Power down settings remembered at power up for easy restart of tests
- 1-year and 2-year specifications and traceable certificate of calibration
Each Unit Includes
- AC175 alligator clips (1 set)
- TL75 test leads (1 set)
- TC Cap for TC hole
- Mini standard TC plugs (with 80cm TC wire)
- package (Including Type K)
- 4 AA alkaline batteries
- Magnet Strap TPAK
- 714B Safety Sheet
- 714B Quick Reference Guide
- 714B Users Manual (available on Fluke’s website)
- Traceable Calilbration Certificate
| Fluke 714B General Specifications |
| Maximum voltage applied between any terminal and earth ground or between any two terminals |
30 V |
| Operating temperature |
-10 °C to 50 °C |
| Storage temperature |
- 30 °C to 60 °C |
| Operating altitude |
2,000 meters |
| Storage altitude |
12,000 meters |
| Relative humidity (% RH operating without condensation) |
Non condensing |
| 90% (10 °C to 30 °C) |
| 75% (30 °C to 40 °C) |
| 45% (40 °C to 50 °C) |
| (Without condensation) |
| Vibration requirements |
MIL-T-28800E, Class 2 |
| Drop text requirements |
1 meter |
| IP Rating |
IEC 60529: IP52 |
| Electromagnetic environment |
IEC 61326-1, Portable |
| Safety |
IEC 61010-1, Max 30 V to earth, Pollution Degree 2 |
| Power supply |
4 AA NEDA 1.5A IEC LR6 batteries |
| Size (H x W x L) |
52.5 mm x 84 mm x 188.5 mm |
| Weight |
515 g |
| DC mA Measurement |
| Resolution |
0-24 mA |
| Range |
0.001 mA |
| Accuracy (% of reading + counts) |
0.010% + 2 µA |
| Temperature coefficient |
± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C) |
| Millivolt Measurement and Source |
| Resolution |
-10 mV to 75 mV |
| Range |
0.01 mV |
| Accuracy (% of reading +counts) |
0.015% + 10 µA |
| Temperature coefficient |
± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C) |
| Thermocouple Input and Output |
| TC Type |
Range (°C) |
Measure (°C) |
Source (°C) |
| 1 year |
2 year |
1 year |
2 year |
| E |
-250 to 200 °C |
1.3 |
2.0 |
0.6 |
0.9 |
| -200 to -100 °C |
0.5 |
0.8 |
0.3 |
0.4 |
| -100 to 600 °C |
0.3 |
0.4 |
0.3 |
0.4 |
| 600 to 1000 °C |
0.4 |
0.6 |
0.2 |
0.3 |
| N |
-200 to -100 °C |
1.0 |
1.5 |
0.6 |
0.9 |
| -100 to 900 °C |
0.5 |
0.8 |
0.5 |
0.8 |
| 900 to 1300 °C |
0.6 |
0.9 |
0.3 |
0.4 |
| J |
-210 to -100 °C |
0.6 |
0.9 |
0.3 |
0.4 |
| -100 to 800 °C |
0.3 |
0.4 |
0.2 |
0.3 |
| 800 to 1200 °C |
0.5 |
0.8 |
0.3 |
0.3 |
| K |
-200 to -100 °C |
0.7 |
1.0 |
0.4 |
0.6 |
| -100 to 400 °C |
0.3 |
0.4 |
0.3 |
0.4 |
| 400 to 1200 °C |
0.5 |
0.8 |
0.3 |
0.4 |
| 1200 to 1372 °C |
0.7 |
1.0 |
0.3 |
0.4 |
| T |
-250 to -200 °C |
1.7 |
2.5 |
0.9 |
1.4 |
| -200 to 0 °C |
0.6 |
0.9 |
0.4 |
0.6 |
| 0 to 400 °C |
0.3 |
0.4 |
0.3 |
0.4 |
| B |
600 to 800 °C |
1.3 |
2.0 |
1.0 |
1.5 |
| 800 to 1000 °C |
1.0 |
1.5 |
0.8 |
1.2 |
| 1000 to 1820 °C |
0.9 |
1.3 |
0.8 |
1.2 |
| R |
-20 to 0 °C |
2.3 |
2.8 |
1.2 |
1.8 |
| 0 to 100 °C |
1.5 |
2.2 |
1.1 |
1.7 |
| 100 to 1767 °C |
1.0 |
1.5 |
0.9 |
1.4 |
| S |
-20 to 0 °C |
2.3 |
2.8 |
1.2 |
1.8 |
| 0 to 200 °C |
1.5 |
2.1 |
1.1 |
1.7 |
| 200 to 1400 °C |
0.9 |
1.4 |
0.9 |
1.4 |
| 1400 to 1767 °C |
1.1 |
1.7 |
1.0 |
1.5 |
| C |
0 to 800 °C |
0.6 |
0.9 |
0.6 |
0.9 |
| 800 to 1200 °C |
0.8 |
1.2 |
0.7 |
1.0 |
| 1200 to 1800 °C |
1.1 |
1.6 |
0.9 |
1.4 |
| 1800 to 2316 °C |
2.0 |
3.0 |
1.3 |
2.0 |
| L |
-200 to -100 °C |
0.6 |
0.9 |
0.3 |
0.4 |
| -100 to 800 °C |
0.3 |
0.4 |
0.2 |
0.3 |
| 800 to 900 °C |
0.5 |
0.8 |
0.2 |
0.3 |
| U |
-200 to 0 °C |
0.6 |
0.9 |
0.4 |
0.6 |
| 0 to 600 °C |
0.3 |
0.4 |
0.3 |
0.4 |
| BP |
0 to 1000 °C |
1.0 |
1.5 |
0.4 |
0.6 |
| 1000 to 2000 °C |
1.6 |
2.4 |
0.6 |
0.9 |
| 2000 to 2500 °C |
2.0 |
3.0 |
0.8 |
1.2 |
| XK |
-200 to 300 °C |
0.2 |
0.3 |
0.2 |
0.5 |
| 300 to 800 °C |
0.4 |
0.6 |
0.3 |
0.6 |
| G |
100 to 300 °C |
1.6 |
2.4 |
1.2 |
1.8 |
| 300 to 1500 °C |
1.0 |
1.5 |
1.0 |
1.5 |
| 1500 to 2320 °C |
2.0 |
3.0 |
1.6 |
2.4 |
| D |
0 to 300 °C |
1.6 |
2.4 |
1.2 |
1.8 |
| 300 to 1500 °C |
1.0 |
1.5 |
1.0 |
1.5 |
| 1500 to 2315 °C |
2.0 |
3.0 |
1.6 |
2.4 |
| P |
0 to 1000 °C |
1.6 |
2.4 |
0.6 |
0.9 |
| 1000 to 1395 °C |
2.0 |
3.0 |
0.8 |
1.2 |
| M |
-50 to 100 °C |
1.0 |
1.5 |
0.4 |
0.6 |
| 100 to 1000 °C |
1.6 |
2.4 |
0.6 |
0.9 |
| 1000 to 1410 °C |
2.0 |
3.0 |
0.8 |
1.2 |
| Process / Calibration/Temperature Calibration/Thermocouple Calibrators Template |
| Type |
Hand Held |
| Measure Inputs |
Yes |
| Source Outputs |
Yes |
| Display (Thermocouple Calibrators) |
Digital |
| Thermocouple Selection |
B, C, D, E, G, J, K, L, N, Other, P, R, S, T, U |
| T/C Measurement Accuracy |
± (0.002 % of reading + 0.002 % of range) /°C ( <1 |
| T/C Source Accuracy |
± (0.002 % of reading + 0.002 % of range) /°C ( <1 |
| T/C Measurement Resolution |
0.01 mV 0.015 % + 10 μA |
| T/C Source Resolution |
0.001 mA 0.010 % + 2 μA |
| Measure RTD |
Yes |
| Measure Frequency |
No |
| Measure Resistance |
No |
| Measure Voltage |
Yes |
| Measure Current |
Yes |
| Measure Thermistor |
No |
| Programable |
No |
| Min/Max Memory |
No |
| Pulse Excitation Compatible |
No |
| Auto Step/Ramp |
No |
| Backlit Display |
No |
| Intrinsically Safe |
No |
| Data Logging |
No |
| Unique Features |
The 714B can measure and simulate (17) different thermocouple types and millivolts
Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
Hanging tool designed in and included with every unit
Configurable 0 % and 100 % source settings for quick 25 % linearity checks
Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
Dual inputs and backlit display for easy interpretation of measurements
Power down settings remembered at power up for easy restart of tests
1-year and 2-year specifications and traceable certification of calibration
|
| Warranty |
1 YEARS |
| Power Supply Voltage |
Battery Powered |
| IP Rating |
IP52 |
| Product Weight |
2.03 LBS |
| Battery Type |
AA |
| Product Height |
2.56 IN |
| Product Length |
9.65 IN |
| Product Width |
7.09 IN |
| Shipping Weight |
2.23 LBS |
| ECCN Number |
EAR99 |
| HTS/Schedule B Number |
9030.39.0100 |
| Country of Origin |
China |
| Shipping Height |
5.91 IN |
| Shipping Length |
12.99 IN |
| Shipping Width |
11.02 IN |
| UPC |
095969050685 |
|
Temp. Probes
| Product |
Price |
 |
Fluke 700TC1
Catalog #: 620119
TC Mini-Plug Kit (Ten Types)
|
$148.25
|
 |
Fluke 700TC2
Catalog #: 620127
T/C Mini-Plug Kit Type J,K,T,E,R,S
|
$148.25
|
 |
Fluke 80CJ-M
Catalog #: 833046
Type J Male Mini-Connectors
|
$60.24
|
 |
Fluke 80CK-M
Catalog #: 779942
Mini-Connector (Type K)
|
$60.24
|
 |
Fluke 80PJ-1
Catalog #: 1288191
Bead Probe
|
$60.24
|
 |
Fluke 80PK-10
Catalog #: 3439199
Pipe Clamp Temperature Probe
|
$335.24
|
 |
Fluke 80PK-11
Catalog #: 2724500
Type-K Velcro Thermocouple Temperature Probe
|
$80.24
|
 |
Fluke 80PK-22
Catalog #: 2098684
SureGrip Immersion Temperature Probe
|
$150.25
|
 |
Fluke 80PK-24
Catalog #: 2098691
SureGrip Air Temperature Probe
|
$167.24
|
 |
Fluke 80PK-25
Catalog #: 2098706
SureGrip Piercing Temperature Probe
|
$167.24
|
 |
Fluke 80PK-26
Catalog #: 2098714
SUREGRIP, TAPERED TEMPERATURE PROBE
|
$167.24
|
 |
Fluke 80PK-27
Catalog #: 2098723
SureGrip Industrial Surface Temperature Probe
|
$429.24
|
 |
Fluke 80PK-3A
Catalog #: 874610
Surface Probe
|
$219.24
|
 |
Fluke 80PK-8
Catalog #: 200360
Pipe Clamp Temperature Probe
|
$239.24
|
 |
Fluke 80PT-25
Catalog #: 2104397
SureGrip Piercing Temperature Probe
|
$162.24
|
Accessories
|
|
|