Fluke 714B
Catalog #: 4387869
Thermocouple Temperature Calibrator
- Overview
- Specifications
- Summary
- Temp. Probes
- Accessories
Product Highlights
- The 714B can measure and simulate (17) different thermocouple types and millivolts
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Hanging tool designed in and included with every unit
- Configurable 0% and 100% source settings for quick 25% linearity checks
- Linear ramp and 25% step auto ramp based on 0% and 100% settings
- Dual inputs and backlit display for easy interpretation of measurements
- Power down settings remembered at power up for easy restart of tests
- 1-year and 2-year specifications and traceable certificate of calibration
Each Unit Includes
- AC175 alligator clips (1 set)
- TL75 test leads (1 set)
- TC Cap for TC hole
- Mini standard TC plugs (with 80cm TC wire)
- package (Including Type K)
- 4 AA alkaline batteries
- Magnet Strap TPAK
- 714B Safety Sheet
- 714B Quick Reference Guide
- 714B Users Manual (available on Fluke’s website)
- Traceable Calilbration Certificate
Fluke 714B General Specifications |
Maximum voltage applied between any terminal and earth ground or between any two terminals |
30 V |
Operating temperature |
-10 °C to 50 °C |
Storage temperature |
- 30 °C to 60 °C |
Operating altitude |
2,000 meters |
Storage altitude |
12,000 meters |
Relative humidity (% RH operating without condensation) |
Non condensing |
90% (10 °C to 30 °C) |
75% (30 °C to 40 °C) |
45% (40 °C to 50 °C) |
(Without condensation) |
Vibration requirements |
MIL-T-28800E, Class 2 |
Drop text requirements |
1 meter |
IP Rating |
IEC 60529: IP52 |
Electromagnetic environment |
IEC 61326-1, Portable |
Safety |
IEC 61010-1, Max 30 V to earth, Pollution Degree 2 |
Power supply |
4 AA NEDA 1.5A IEC LR6 batteries |
Size (H x W x L) |
52.5 mm x 84 mm x 188.5 mm |
Weight |
515 g |
DC mA Measurement |
Resolution |
0-24 mA |
Range |
0.001 mA |
Accuracy (% of reading + counts) |
0.010% + 2 µA |
Temperature coefficient |
± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C) |
Millivolt Measurement and Source |
Resolution |
-10 mV to 75 mV |
Range |
0.01 mV |
Accuracy (% of reading +counts) |
0.015% + 10 µA |
Temperature coefficient |
± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C) |
Thermocouple Input and Output |
TC Type |
Range (°C) |
Measure (°C) |
Source (°C) |
1 year |
2 year |
1 year |
2 year |
E |
-250 to 200 °C |
1.3 |
2.0 |
0.6 |
0.9 |
-200 to -100 °C |
0.5 |
0.8 |
0.3 |
0.4 |
-100 to 600 °C |
0.3 |
0.4 |
0.3 |
0.4 |
600 to 1000 °C |
0.4 |
0.6 |
0.2 |
0.3 |
N |
-200 to -100 °C |
1.0 |
1.5 |
0.6 |
0.9 |
-100 to 900 °C |
0.5 |
0.8 |
0.5 |
0.8 |
900 to 1300 °C |
0.6 |
0.9 |
0.3 |
0.4 |
J |
-210 to -100 °C |
0.6 |
0.9 |
0.3 |
0.4 |
-100 to 800 °C |
0.3 |
0.4 |
0.2 |
0.3 |
800 to 1200 °C |
0.5 |
0.8 |
0.3 |
0.3 |
K |
-200 to -100 °C |
0.7 |
1.0 |
0.4 |
0.6 |
-100 to 400 °C |
0.3 |
0.4 |
0.3 |
0.4 |
400 to 1200 °C |
0.5 |
0.8 |
0.3 |
0.4 |
1200 to 1372 °C |
0.7 |
1.0 |
0.3 |
0.4 |
T |
-250 to -200 °C |
1.7 |
2.5 |
0.9 |
1.4 |
-200 to 0 °C |
0.6 |
0.9 |
0.4 |
0.6 |
0 to 400 °C |
0.3 |
0.4 |
0.3 |
0.4 |
B |
600 to 800 °C |
1.3 |
2.0 |
1.0 |
1.5 |
800 to 1000 °C |
1.0 |
1.5 |
0.8 |
1.2 |
1000 to 1820 °C |
0.9 |
1.3 |
0.8 |
1.2 |
R |
-20 to 0 °C |
2.3 |
2.8 |
1.2 |
1.8 |
0 to 100 °C |
1.5 |
2.2 |
1.1 |
1.7 |
100 to 1767 °C |
1.0 |
1.5 |
0.9 |
1.4 |
S |
-20 to 0 °C |
2.3 |
2.8 |
1.2 |
1.8 |
0 to 200 °C |
1.5 |
2.1 |
1.1 |
1.7 |
200 to 1400 °C |
0.9 |
1.4 |
0.9 |
1.4 |
1400 to 1767 °C |
1.1 |
1.7 |
1.0 |
1.5 |
C |
0 to 800 °C |
0.6 |
0.9 |
0.6 |
0.9 |
800 to 1200 °C |
0.8 |
1.2 |
0.7 |
1.0 |
1200 to 1800 °C |
1.1 |
1.6 |
0.9 |
1.4 |
1800 to 2316 °C |
2.0 |
3.0 |
1.3 |
2.0 |
L |
-200 to -100 °C |
0.6 |
0.9 |
0.3 |
0.4 |
-100 to 800 °C |
0.3 |
0.4 |
0.2 |
0.3 |
800 to 900 °C |
0.5 |
0.8 |
0.2 |
0.3 |
U |
-200 to 0 °C |
0.6 |
0.9 |
0.4 |
0.6 |
0 to 600 °C |
0.3 |
0.4 |
0.3 |
0.4 |
BP |
0 to 1000 °C |
1.0 |
1.5 |
0.4 |
0.6 |
1000 to 2000 °C |
1.6 |
2.4 |
0.6 |
0.9 |
2000 to 2500 °C |
2.0 |
3.0 |
0.8 |
1.2 |
XK |
-200 to 300 °C |
0.2 |
0.3 |
0.2 |
0.5 |
300 to 800 °C |
0.4 |
0.6 |
0.3 |
0.6 |
G |
100 to 300 °C |
1.6 |
2.4 |
1.2 |
1.8 |
300 to 1500 °C |
1.0 |
1.5 |
1.0 |
1.5 |
1500 to 2320 °C |
2.0 |
3.0 |
1.6 |
2.4 |
D |
0 to 300 °C |
1.6 |
2.4 |
1.2 |
1.8 |
300 to 1500 °C |
1.0 |
1.5 |
1.0 |
1.5 |
1500 to 2315 °C |
2.0 |
3.0 |
1.6 |
2.4 |
P |
0 to 1000 °C |
1.6 |
2.4 |
0.6 |
0.9 |
1000 to 1395 °C |
2.0 |
3.0 |
0.8 |
1.2 |
M |
-50 to 100 °C |
1.0 |
1.5 |
0.4 |
0.6 |
100 to 1000 °C |
1.6 |
2.4 |
0.6 |
0.9 |
1000 to 1410 °C |
2.0 |
3.0 |
0.8 |
1.2 |
Process / Calibration/Temperature Calibration/Thermocouple Calibrators Template |
Type |
Hand Held |
Measure Inputs |
Yes |
Source Outputs |
Yes |
Display (Thermocouple Calibrators) |
Digital |
Thermocouple Selection |
B, C, D, E, G, J, K, L, N, Other, P, R, S, T, U |
T/C Measurement Accuracy |
± (0.002 % of reading + 0.002 % of range) /°C ( <1 |
T/C Source Accuracy |
± (0.002 % of reading + 0.002 % of range) /°C ( <1 |
T/C Measurement Resolution |
0.01 mV 0.015 % + 10 μA |
T/C Source Resolution |
0.001 mA 0.010 % + 2 μA |
Measure RTD |
Yes |
Measure Frequency |
No |
Measure Resistance |
No |
Measure Voltage |
Yes |
Measure Current |
Yes |
Measure Thermistor |
No |
Programable |
No |
Min/Max Memory |
No |
Pulse Excitation Compatible |
No |
Auto Step/Ramp |
No |
Backlit Display |
No |
Intrinsically Safe |
No |
Data Logging |
No |
Unique Features |
The 714B can measure and simulate (17) different thermocouple types and millivolts
Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
Hanging tool designed in and included with every unit
Configurable 0 % and 100 % source settings for quick 25 % linearity checks
Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
Dual inputs and backlit display for easy interpretation of measurements
Power down settings remembered at power up for easy restart of tests
1-year and 2-year specifications and traceable certification of calibration
|
Warranty |
1 YEARS |
Power Supply Voltage |
Battery Powered |
IP Rating |
IP52 |
Product Weight |
2.03 LBS |
Battery Type |
AA |
Product Height |
2.56 IN |
Product Length |
9.65 IN |
Product Width |
7.09 IN |
Shipping Weight |
2.23 LBS |
ECCN Number |
EAR99 |
HTS/Schedule B Number |
9030.39.0100 |
Country of Origin |
China |
Shipping Height |
5.91 IN |
Shipping Length |
12.99 IN |
Shipping Width |
11.02 IN |
UPC |
095969050685 |
|
Temp. Probes
Product |
Price |
|
Fluke 700TC1
Catalog #: 620119
TC Mini-Plug Kit (Ten Types)
|
$145.24
|
|
Fluke 700TC2
Catalog #: 620127
T/C Mini-Plug Kit Type J,K,T,E,R,S
|
$145.24
|
|
Fluke 80CJ-M
Catalog #: 833046
Type J Male Mini-Connectors
|
$60.24
|
|
Fluke 80CK-M
Catalog #: 779942
Mini-Connector (Type K)
|
$60.24
|
|
Fluke 80PJ-1
Catalog #: 1288191
Bead Probe
|
$60.24
|
|
Fluke 80PK-10
Catalog #: 3439199
Pipe Clamp Temperature Probe
|
$335.24
|
|
Fluke 80PK-11
Catalog #: 2724500
Type-K Velcro Thermocouple Temperature Probe
|
$80.24
|
|
Fluke 80PK-22
Catalog #: 2098684
SureGrip Immersion Temperature Probe
|
$141.24
|
|
Fluke 80PK-24
Catalog #: 2098691
SureGrip Air Temperature Probe
|
$167.24
|
|
Fluke 80PK-25
Catalog #: 2098706
SureGrip Piercing Temperature Probe
|
$167.24
|
|
Fluke 80PK-26
Catalog #: 2098714
SUREGRIP, TAPERED TEMPERATURE PROBE
|
$167.24
|
|
Fluke 80PK-27
Catalog #: 2098723
SureGrip Industrial Surface Temperature Probe
|
$429.24
|
|
Fluke 80PK-3A
Catalog #: 874610
Surface Probe
|
$219.24
|
|
Fluke 80PK-8
Catalog #: 200360
Pipe Clamp Temperature Probe
|
$239.24
|
|
Fluke 80PT-25
Catalog #: 2104397
SureGrip Piercing Temperature Probe
|
$162.24
|
Accessories
|
|
|