| Fluke Networks CertiFiber® Pro Optical Loss Test Set Specifications | 
        
        
            | Power Meter Specifications | 
        
        
            | Input Connector | 
            Interchangeable connector adapter (LC standard, SC, ST and FC optional) | 
        
        
            | Detector Type | 
            InGaAs | 
        
        
            | Wavelengths | 
            850 nm, 1300 nm, 1310 nm, 1550 nm | 
        
        
            | Power Measurement Range | 
            0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) | 
        
        
            | Power Measurement Uncertainty1,2 | 
            < +/- 5% +/- 32 pW | 
        
        
            | Measurement Linearity3 | 
            < ± 0.1 dB | 
        
        
            | Re-calibration Period | 
            1 year | 
        
        
            1. +/- 100 pW at 850 nm 
            2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST. 
            3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up. | 
        
        
            | Loss/Length Specifications | 
        
        
            | Specification | 
            CertiFiber Pro Multimode Modules | 
            CertiFiber Pro Singlemode Modules | 
        
        
            | Testing Speeds (excludes referencing times) | 
            Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection) 
            Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) 
            Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) | 
        
        
            | Input/Output Connectors | 
            Interchangeable connector adapter (LC standard, SC, ST and FC optional) | 
        
        
            | Launch Condition1,2 | 
            Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 | 
        
        
            | Fiber Types Tested | 
            50/125 µm or 62.5/125 µm | 
            singlemode | 
        
        
            | Source Type and Wavelengths | 
            LED source 850 nm ± 30 nm 1300 nm ± 20 nm | 
            Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm | 
        
        
            | Maximum Length Measurement | 
            12 km | 
            130 km | 
        
        
            | Length Measurement Accuracy | 
            ± 1.5 m plus ± 1 % of length | 
            ± 1.5 m plus ± 1 % of length | 
        
        
            | Output Power (Nominal) | 
            ≥ -24 dBm with EF-TRC | 
            ≥ -4 dBm | 
        
        
            | Output Power Stability3 | 
            ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes | 
            ± 0.1 dB over 8 hours ± 0.08 dB over 15 minutes | 
        
        
            1. At the output of the EF-TRC 
            2. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor 
            3. Relative to power level after 15 minute warm up – at constant temperature | 
        
        
            | Loss/Length Specifications (continued) | 
        
        
            | Source Wavelengths | 
            850 nm, 1300 nm, 1310 nm, 1550 nm | 
        
        
            | Power Measurement Range | 
            0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) | 
        
        
            | Power Measurement Uncertainty1, 2 | 
            < +/- 5% +/- 32 pW | 
        
        
            | Measurement Linearity3 | 
            < ± 0.1 dB | 
        
        
            | Re-calibration Period | 
            1 year | 
        
        
            1. +/- 100 pW at 850 nm 
            2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 | 
        
        
            | Selected Specifications | 
        
        
            | Visual Fault Locator (VFL) | 
        
        
            | Title | 
            Requirement | 
        
        
            | Output Power | 
            >-5 dBm 
            <0 dBm 
            SMF-28 singlemode fiber 
            Continuous wave 
            SC/UPC connector | 
        
        
            | Operating Wavelength | 
            650 nm nominal | 
        
        
            | Output Modes | 
            Continuous wave 
            Pulsed mode (2 Hz to 3 Hz blink frequency) | 
        
        
            | Connector Adapter | 
            2.5 mm universal | 
        
        
            | Laser Safety | 
            Class II CDRH 
            Over operating temperature range | 
        
        
            | Environmental Specifications | 
        
        
            | Title | 
            Requirement | 
        
        
            | Operating Temperature | 
            -18° C to 45° C | 
        
        
            | Storage Temperature | 
            -30° C to +60° C | 
        
        
            Operating Relative Humidity 
            % RH without condensation | 
            0 % to 90 %, 32 °F to 95 °F (0° C to 35° C) 
            0 % to 70 %, 95 °F to 113 °F (35° C to 45° C) | 
        
        
            | Vibration | 
            Random, 2 g, 5 Hz-500 Hz | 
        
        
            | Shock | 
            1 m drop test with and without module and adapters | 
        
        
            | Safety | 
            CSA C22.2 No. 1010.1: 1992 
            EN 61010-1 1st Edition + Amendments 1, 2 | 
        
        
            | Pollution Degree | 
            2 | 
        
        
            | Altitude | 
            Operating: 4,000 m; storage: 12,000 m | 
        
        
            | EMC | 
            EN 61326–1 |