AC current (50 - 60 Hz) |
Range |
Accuracy |
0-40.00 A |
±1.9% ±10 digits |
40.00-200.0 A |
±1.9% ±5 digits |
201-400 A |
±1.9% ±5 digits |
|
Position error |
±1.5% of reading |
DC Range |
0 - 200.0 V |
AC Range |
200.0 - 600.0 V |
Accuracy |
DC |
±1.0% ±2 dgts |
AC |
±1.5% ±5 dgts (50-500 Hz) |
Continuity buzzer |
On |
<20 Ω |
Off |
>50 Ω |
Response time |
<50 ms |
Resistance |
Range |
Accuracy |
200.0 Ω |
±1% ±5% digits |
2.000 KΩ |
±0.7% ±2 digits |
20.00 KΩ |
±0.7% ±2 digits |
200.0 KΩ |
±0.7% ±2 digits |
2.000 MΩ |
±1.0% ±2 digits |
20.00 MΩ |
±1.9% ±5 digits |
|
Overrange display |
"OL" |
Sample rate |
2.5 times per second |
Power Requirements |
2 x AAA 1.5 A Alkaline Battery |
Battery Life |
200 hours |
Auto Off |
10 mins. after power off |
Safety rating |
IEC/EN61010-1 CAT III 600 V |
Temperature Coefficient |
0.2 x (specified accuracy) / ºC (<18ºC >28ºC) |
Maximum Conductor Size |
27 mm diameter |
LCD |
2000 digit large scale readout |
Storage Temperature |
-20ºC - +60ºC (80% RH) (batteries removed) |
Operating Altitude |
2000 m |
EMC |
IEC/EN 61326-1 |
Dimensions |
56 mm (W) x 188 mm (H) x 28 mm (D) |
Weight |
225 g including batteries |
Warranty |
1 year |
All accuracies specified at 23ºC ±5º 85% RH |