Megger CFL510G
Catalog #: 1001-790
Handheld Time Domain Reflectometer, 0.3 ft. Min., 15,000 ft. Max. Range
- Overview
- Specifications
- Summary
- Accessories
Product Highlights
- Alternative name for Megger TDR1000/3
- An AUTO selection option ensures that the most effective parameters are chosen, depending on the range required, aiding rapid diagnosis of the TDR trace.
- Dual cursors allow complete flexibility, giving the user full control and instant indication of distance between two points.
- A unique, easy one-button press and HOLD feature allows comparison between cable conditions.
- Extra high resolution, a white-light backlight, and grayscale tones gives a vibrant graphical display, useful
- in identifying key events on the trace.
- Additional features include:
- Backlit graphics monochrome LCD (256 x 128)
- Adjustable display contrast
- Resolution to 0.1 m
- For use on telecom circuit or 150 V CATIV power circuit
- Power blocking filter not required
- Environmental protection to IP54
- Auto selected output impedance (between 25, 50, 75 and 100 ohms)
- 2 ns pulse for near-end fault location
- AUTO option selecting gain and pulse for each range
- Display distance in meters or feet
- Uses five AA (LR6) batteries
Each Unit Includes
- 1 - CFL510G Handheld TDR (1001-790)
- 1 - Miniature Clip Test Lead Set (6231-652)
- 1 - Bed of Nails Test Lead Set (6231-653)
- 1 - Socket BNC to 2x4mm, 50 Ohm (25965-154)
- 1 - Hard Carrying Case (5410-420)
- 1 - User Guide CD
SPECIFICATIONS |
Ranges |
30 ft, 75 ft, 300 ft, 750 ft, 3000 ft, 7500 ft, and 15,000 ft
(10 m, 25 m, 100 m, 250 m, 1000 m, 2500 m, and 5000 m) |
Accuracy |
±1% of range ± pixel at 0.67 VF
(The measurement accuracy is for the ndicated cursor position only and is conditional on the velocity factory being correct.) |
Input Protection |
Complies with IEC61010-1 for connection to live systems up to 150 V CAT IV when used with the optional fused test lead set. |
Output Pulse |
5 V peak to peak into open circuit. Pulse widths determined by range and cable. |
Gain |
Set for each range with three user selectable steps (in manual operating mode) |
Velocity Factor |
Variable from 0.2 to 0.99 in steps of 0.01 |
TX Null |
Automatic |
Power Down |
Automatic after 5 minutes with no key press |
Backlight |
Stays on for one minute with no key press |
Power |
Five AA (LR6) type batteries, manganese-alkali or nickel metal-dydride cells |
Battery Life |
Up to 14 hours (typical) |
Mechanical |
Designed for indoor or outdoor use, rated to IP54 |
Case Dimensions |
9 in. x 4.5 in. x 2 in.
(230 mm x 115 mm x 48 mm) |
Instrument Weight |
1.32 lbs (0.6 kg) |
Case Material |
ABS |
Connectors |
Two 4 mm-safety terminals |
Display |
256 x 128 pixels, graphics LCD |
Environmental |
Operational Temperature |
5°F to 122°F (-15°C to +50°C) |
Storage Temperature |
-4°F to +158°F (-20?C to +70°C) |
Country of Origin |
United Kingdom |
|
|
|
|