Product Highlights

  • Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard
  • GPS time synchronization: Correlate data with events or datasets from other instruments with precision
  • Flexible and fully configurable thresholds and scale factors:Allows user to pinpoint specific issues by defining the detailed criteria for detection and recording of disturbances.
  • Uninterrupted power supply (40 minutes): Never miss important events - even record the beginning and end of interruptions and outages to help determine the cause
  • 10 MHz, 6000 Vpk waveform capture: Get a detailed picture of even the shortest event
  • 2 GB data memory: Enables detailed, simultaneous recording of numerous power parameters for long periods of time
  • Comprehensive software included: Provides trend diagrams for root cause analysis, statistical summaries, report writing and real-time data monitoring in the online mode
  • Plug and play: Allows quick setup with automatic sensor detection; sensors are instrument powered, eliminating the need for batteries
  • Rugged field design: Insulated housing and a solid state design with no rotating components enable reliable testing under nearly any conditions

Each Unit Includes

  • Internal Flash-memory 2 GB
  • PQ Analyze software on CD-ROM
  • Ethernet cable for network connection (1)
  • Crosslink Ethernet cable for direct PC connection (1)
  • Mains cable (1)
  • Operational manuals
  • Carrying bag
  • Voltage probes, qty 4 (600 V for INTL set, 1000 V for US set)
  • Current probes, qty 4 (Dual-range flexible current probes 1000 A / 200 A AC)
  • GPS time sync receiver

 

Technical Data
Overview of Measurement Functions
Statistical Evaluation Power quality statistics according to EN50160 and DISDIP tables like ITIC, CEBEMA, ANSI
Continuous Recording Fluke 1760 records rms values together with corresponding minimum and maximum values for:
  • Voltage
  • Current
  • Power P, Q, S
  • Power Factor
  • kWh
  • Flicker
  • Unbalance
  • Frequency
  • Harmonics/Interharmonics

continuously with the following time aggregations:
Day
10 min
Free Interval, e.g.: 15 min, 2h

Triggered Recordings rms: Aggregation time is adjustable between 10 ms (1/2 cycle), 20ms (1 cycle), 200ms (10/12 cycles) or 3 sec (150/180 cycles).
Calculating rms values, Harmonics and Interharmonics is performed synchronous to the power frequency. Basic aggregation for harmonics and interharmonics is 200ms
Oscilloscope: Sample rate is 10.24 kHz for all 8 channels
Fast Transients: Sample rate is selectable from 100 kHz to 10 MHz for channel 1-4 FFT of Fast Transients
Mains Signalling Phases and N-conductor, Voltage and current
Online Mode Variable refresh rate. This feature allows verification of instrument set up and delivers a quick overview of oscilloscope, transients and events.
General Data
Intrinsic uncertainty refers to reference conditions and is guaranteed for two years
Quality system developed, manufactured as per ISO 9001: 2000
Environment conditions
Operating temperature range: 0 °C to +50 °C; 32 °F to +122 °F
Working temperature range: -20 °C to +50 °C; -4 °F to +122 °F
Storage temperature range: 20 °C to +60 °C; -4 °F to 140 °F
Reference temperature: 23 °C ± 2 K; 74 °F ± 2 K
Climatic class: B2 (IEC 654-1), -20 °C to +50 °C; -4 °F to +122 °F
Max. operating altitude: 2000 m: max. 600 V CAT IV*, power supply: 300 V CAT
2000 m: max. 600 V CAT IV*, power supply: 300 V CAT III 5000 m: max 600 V CAT III*, power supply: 300 V CAT II
* depending on sensor
Reference conditions
Environment temperature: 23 °C ± 2 K ; 74°F ± 2 K
Power supply: 230 V ± 10 %
Power frequency: 50 Hz / 60 Hz
Signal: declared input voltage Udin
Averaging: 10 minute intervals
Housing insulated, robust plastics housing
EMC
Emission: Class-A as per IEC/EN 61326-1
Immunity: IEC/EN 61326-1
Power supply
Range: AC: 83 V to 264 V, 45 to 65 Hz
DC: 100 V to 375 V
Safety: IEC/EN 61010-1 2nd edition
300 V CAT III
Power consumption: max. 54VA
Battery pack: NIMH, 7.2 V, 2.7 Ah
In case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged accumulators the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as the supply voltage returns. The battery can be replaced by the user.
Display
  Fluke 1760 features LED indicators for the status of the 8 channels, phase sequence, power supply (mains or accumulator), memory usage, time synchronization, and data transfer.
Power LED: • Permanent light: normal power supply from mains.
• OFF: supply via internal accumulator in case of a power failure.
Channel LEDs 3-color LEDs per channel for:
• overload condition
• under load condition
signal level in nominal range
Data memory 2 GB Flash memory depending on model
Memory model Linear
Interfaces Ethernet (100MB/s), compatible to Windows® 98/ME/NT/2000/XP RS 232, external modem via RS 232
Baud rate for RS 232 9600 Baud to 115 kBaud
Dimensions 325 mm x 300 m x 65 mm; 2.8 x 11.8 x 2.6 in. (H x W x D)
Weight appr. 4.9 kg; 10.8 lbs. (without accessories)
Warranty 2 years
Calibration interval 1 year recommended for Class-A, otherwise 2 years
Signal Conditioning
Range for 50 Hz systems 50 Hz ± 15 % (42.5 Hz to 57.5 Hz)
Range for 60 Hz systems 60 Hz ± 15 % (51 Hz to 69 Hz)
Resolution 16 ppm
Sampling frequency for 50 Hz power frequency 10.24 kHz, The sampling rate is synchronized to mains frequency.
Uncertainty for frequency measurements < 20 ppm
Uncertainty of internal clock < 1s / day
Measurement intervals
  Aggregation of the interval values as per IEC 61000-4-30 Class-A
Min-, Max-values: Half cycle, e.g.: 10 ms rms values at 50Hz
Transients: Sample rate 100 kHz to 10 MHz per channel
Harmonics as per IEC 61000-4-7:2002: 200 ms
Flicker as per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt)
Measurement Inputs
Number of inputs 8 galvanically isolated inputs for voltage and current measurements.
Sensor safety up to 600 V CAT IV depending on sensor
Basic safety 300 V CAT III
Nominal voltage (rms) 100 mV
Range (peak value) 280 mV
Overload capacity (rms) 1000 V, continuously
Voltage rise rate max. 15 kV / µs
Input resistance 1 MΩ
Input capacitance 5 pF
Input filter Each channel is equipped with a passive low-pass filter, an anti-aliasing filter and a 16-bit A/D converter. All channels are sampled synchronously with a common quartz-controlled clock pulse.
The filters protect against voltage transients and limit the signal rise rate, reduce high frequency components and especially the noise voltage above half the sampling rate of the A/D converter by 80 dB, thus achieving very small measuring errors in an exceptionally large amplitude range. This is also valid under extreme operating conditions like transient voltages at the output of converters.
Uncertainties
Uncertainty at reference conditions
  Uncertainty including the voltage sensors is in compliance with IEC 61000-4-30 Class-A. All voltage sensors are suitable for DC up to 5 kHz
With Sensor 1000 V 0,1% at Udin = 480 V and 600 V P-N
Sensor 600 V 0,1% at Udin = 230 V P-N
Intrinsic uncertainty for harmonics Class I as per EN 61000-4-7:2002
Reference conditions 23 °C ± 2 K < 60 % rH; 74 °F ± 2 K < 60 % rH
Warmed up instrument > 3h
Power supply: 100 V to 250 V ac
Temperature drift 100 ppm / K
Aging < 0.05 % / year
Common mode rejection > 100 dB at 50 Hz
Temperature drift Change of amplification through temperature: < 0.005 %/K
Aging Change of amplification due to ageing: < 0.04 %/year
Noise Noise voltage, input short-circuited: < 40 µV
DC ± (0.2% rdg + 0.1% sensor)

 

Power Measurement/Power Quality Analyzer Template
Type (Power Quality)  3 Phase
Maximum Voltage AC 1000 V
Maximum Voltage DC 1000 V
True Power / Work ( W)  Yes
Apparent Power (VA)  Yes
Reactive Power (VAR)  Yes
Measurement Frequency (Power Quality) 50 Hz, 60 Hz
Display (Power Quality) Digital
Alarms Yes
Transient Capture  Yes 
Displays Waveform  Yes
Energy  Yes
Phasor Diagrams  No
Power Factor (Power Quality)  Yes
Harmonics  Yes
Maximum Harmonics Range 200 
Current Clamps Included No
Class A Compliant  Yes
Crest Factor Yes 
CAT Rating  IV
Country of Origin Germany
Other Information

Statistical Evaluation: Power quality statistics according to EN50160 and DISDIP tables like ITIC, CEBEMA, ANSI

Continuous Recording: Fluke 1760 records rms values together with corresponding minimum and maximum values for:

  • Voltage
  • Current
  • Power P, Q, S
  • Power Factor
  • kWh
  • Flicker
  • Unbalance
  • Frequency
  • Harmonics/Interharmonics

continuously with the following time aggregations:
Day
10 min
Free Interval, e.g.: 15 min, 2h

 

Triggered Recordings: rms: Aggregation time is adjustable between 10 ms (1/2 cycle), 20ms (1 cycle), 200ms (10/12 cycles) or 3 sec (150/180 cycles).
Calculating rms values, Harmonics and Interharmonics is performed synchronous to the power frequency. Basic aggregation for harmonics and interharmonics is 200ms
Oscilloscope: Sample rate is 10.24 kHz for all 8 channels
Fast Transients: Sample rate is selectable from 100 kHz to 10 MHz for channel 1-4 FFT of Fast Transients

Mains Signalling: Phases and N-conductor, Voltage and current

Online Mode: Variable refresh rate. This feature allows verification of instrument set up and delivers a quick overview of oscilloscope, transients and events.

Intrinsic uncertainty: refers to reference conditions and is guaranteed for two years

Quality system: developed, manufactured as per ISO 9001: 2000

Operating temperature range:: 0 ?C to +50 ?C; 32 ?F to +122 ?F

Working temperature range:: -20 ?C to +50 ?C; -4 ?F to +122 ?F

Storage temperature range:: 20 ?C to +60 ?C; -4 ?F to 140 ?F

Reference temperature:: 23 ?C ? 2 K; 74 ?F ? 2 K

Climatic class:: B2 (IEC 654-1), -20 ?C to +50 ?C; -4 ?F to +122 ?F

Max. operating altitude:: 2000 m: max. 600 V CAT IV*, power supply: 300 V CAT
2000 m: max. 600 V CAT IV*, power supply: 300 V CAT III 5000 m: max 600 V CAT III*, power supply: 300 V CAT II
* depending on sensor

Environment temperature:: 23 ?C ? 2 K ; 74?F ? 2 K

Power supply:: 230 V ? 10 %

Power frequency:: 50 Hz / 60 Hz

Signal:: declared input voltage Udin

Averaging:: 10 minute intervals

Housing: insulated, robust plastics housing

Emission:: Class-A as per IEC/EN 61326-1

Immunity:: IEC/EN 61326-1

Range:: AC: 83 V to 264 V, 45 to 65 Hz
DC: 100 V to 375 V

Safety:: IEC/EN 61010-1 2nd edition
300 V CAT III

Power consumption:: max. 54VA

Battery pack:: NIMH, 7.2 V, 2.7 Ah
In case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged accumulators the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as the supply voltage returns. The battery can be replaced by the user.

 : Fluke 1760 features LED indicators for the status of the 8 channels, phase sequence, power supply (mains or accumulator), memory usage, time synchronization, and data transfer.

Power LED:: ? Permanent light: normal power supply from mains.
? OFF: supply via internal accumulator in case of a power failure.

Channel LEDs: 3-color LEDs per channel for:
? overload condition
? under load condition
signal level in nominal range

Data memory: 2 GB Flash memory depending on model

Memory model: Linear

Interfaces: Ethernet (100MB/s), compatible to Windows? 98/ME/NT/2000/XP RS 232, external modem via RS 232

Baud rate for RS 232: 9600 Baud to 115 kBaud

Dimensions: 325 mm x 300 m x 65 mm; 2.8 x 11.8 x 2.6 in. (H x W x D)

Weight: appr. 4.9 kg; 10.8 lbs. (without accessories)

Warranty: 2 years

Calibration interval: 1 year recommended for Class-A, otherwise 2 years

Range for 50 Hz systems: 50 Hz ? 15 % (42.5 Hz to 57.5 Hz)

Range for 60 Hz systems: 60 Hz ? 15 % (51 Hz to 69 Hz)

Resolution: 16 ppm

Sampling frequency for 50 Hz power frequency: 10.24 kHz, The sampling rate is synchronized to mains frequency.

Uncertainty for frequency measurements: 20 ppm

Uncertainty of internal clock: 1s / day

 : Aggregation of the interval values as per IEC 61000-4-30 Class-A

Min-, Max-values:: Half cycle, e.g.: 10 ms rms values at 50Hz

Transients:: Sample rate 100 kHz to 10 MHz per channel

Harmonics: as per IEC 61000-4-7:2002: 200 ms

Flicker: as per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt)

Number of inputs: 8 galvanically isolated inputs for voltage and current measurements.

Sensor safety: up to 600 V CAT IV depending on sensor

Basic safety: 300 V CAT III

Nominal voltage (rms): 100 mV

Range (peak value): 280 mV

Overload capacity (rms): 1000 V, continuously

Voltage rise rate: max. 15 kV / ?s

Input resistance: 1 MO

Input capacitance: 5 pF

Input filter: Each channel is equipped with a passive low-pass filter, an anti-aliasing filter and a 16-bit A/D converter. All channels are sampled synchronously with a common quartz-controlled clock pulse.
The filters protect against voltage transients and limit the signal rise rate, reduce high frequency components and especially the noise voltage above half the sampling rate of the A/D converter by 80 dB, thus achieving very small measuring errors in an exceptionally large amplitude range. This is also valid under extreme operating conditions like transient voltages at the output of converters.

MEMBER PRICE: INACTIVE
List price:   $30,977.24
Notify me when price changes $

Related products

Cases

Current Clamps

Accessories

Recently viewed products

  • Catalog #: 2630759 Three Phase Power Quality Recorder Topas

    $30,977.24
We Ship Worldwide
Australia
Write us quote request in any language and then immediately translate it to English on our site.
Brazil
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Chile
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
China
您的要求发送给我们以任何语言,它会自动翻译成英文在我们的网站。
France
Envoyez-nous votre demande dans n'importe quelle langue, qui seront ensuite automatiquement traduites en anglais sur notre site.
Germany
Schreiben Sie uns Ihre Anfrage in jeder beliebigen Sprache, diese wird dann auf unserer Website automatisch ins englische übersetzt.
India
हमें किसी भी भाषा में आपके अनुरोध है, जो स्वचालित रूप से हमारी वेबसाइट पर अंग्रेजी में अनुवाद हो जाएगा भेजें.
Italy
Inviaci la tua richiesta in qualsiasi lingua, che sarà automaticamente tradotto in inglese sul nostro sito web.
Japan
任意の言語で、その後は自動的に英語に当社のウェブサイト上に翻訳されますあなたのリクエストを送ってください。
Mexico
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Norway
Send oss din forespørsel på alle språk, som deretter automatisk oversatt til engelsk på våre nettsider.
Philippines
Ipadala sa amin ang inyong kahilingan sa kahit anong wika, na awtomatikong masasalin sa Ingles sa aming website.
Portugal
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
Russian Federation
Отправьте нам свой запрос на любом языке, который будет автоматически переведен на английский на нашем сайте.
Spain
Envíenos su solicitud en cualquier idioma, que luego se traducen automáticamente en Inglés en nuestro sitio web.
United Kingdom
Write us quote request in any language and then immediately translate it to English on our site.
Quote Request
Portuguese Spanish German Hindi Italian Russian
English
Write us quote request in any language and then immediately translate it to English on our site
We Accept Payments
Usamultimeters.com BBB Business Review
Copyright © 2008-2024 usamultimeters.com All Rights Reserved
Products Manufactures Quote Request Resources Cart