Fluke 80I-110S
Catalog #: 114519
AC/DC Current Clamp
- Overview
- Specifications
- Summary
Product Highlights
- Current Range: 0.1 to 100A DC or 0.1 to 70A AC
- Basic Accuracy (DC to 1kHz):
- 100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA
- 10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA
- 40A to 80A +/- 12% of reading + 50mA
- 80 to 100A +/- 15% of reading
- Output Signal: 10A range: 100mV/A | 100A range: 10mV/A
- Bandwidth: 1Hz to 20kHz
- Working Voltage: 600V AC rms
- Maximum Conductor Size: 11.8 mm (.46 inch) diameter
- Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V
Specifications |
Nominal current range |
10 A, AC/DC
100 A, AC/DC |
Continuous current range |
0.1 A - 10 A AC/DC
1 A - 100 A AC/DC |
Maximum Non-Destructive Current |
140 A - 2 kHz |
Lowest measurable current |
0.1 A |
Basic Accuracy |
3% + 50 mA (@ 10 A)
(% reading + floorspec) |
Useable frequency |
DC - 100 kHz |
Output level(s) |
100 mV/A
10 mV/A |
Zero error adjustment |
Yes |
Safety Specifications |
Safety |
CAT II, 600 V
CAT III, 300 V |
Maximum voltage |
600 V |
Mechanical & General Specifications |
Warranty |
1 year |
Battery Life |
9 V, 55 h |
Maximum conductor diameter |
11.8 mm |
Output cable length |
1.6 m |
BNC Adapter |
Yes |
|
|
|
|