				Extech PQ34-30
                
                
                
 			 
            
			
				Catalog #: PQ34-30
 3000A Current Flexible Clamp Probes Set of 3 clamps
			 
			 
              
            
                
                    - Overview
 
                    - Specifications
 
                    - Summary
 
                    
                    
                    
                 
                	
                    
				        
                        Product Highlights 
    - Flexible current probe
 
     
    - Probe latch
 
     
    - Power LED
 
     
    - 3000A-300A-30A range switch
 
     
    - Signal output plugs (+, red; -, black)
 
     
    - DCV power plug
 
     
    - Max conductor size: oval - 8.5"/216mm; round -      7"/177mm
 
 
                        
                            
                    
                          
    
        
            |   | 
            Range | 
         
        
            | Measurement ranges | 
            30A, 300A and 3000A, switch selectable | 
         
        
            | Output sensitivity | 
            100mV/A on the 30A range 
            10mV/A on the 300A range 
            1mV/A on the 3000A range | 
         
        
            | Output coupling | 
            AC coupled. | 
         
        
            | Accuracy (50/60Hz) | 
            ± 1% F.S. @ 23 ± 5°C (50/60Hz) | 
         
        
            | Frequency range | 
            45 to 400 Hz. | 
         
        
            | Max conductor size | 
            Round: (177mm (7"), Oval: 216mm (8.5") | 
         
        
            | Phase error (50/60Hz) | 
            < ± 1° | 
         
        
            | Minimum load | 
            100 K ohm for specified accuracy | 
         
        
            | Linearity | 
            ±0.2% of reading from 10% to 100% of range | 
         
        
            | Phase error | 
            <±1.5° (50/60Hz) | 
         
        
            | Conductor position sensitivity | 
            ± 2% F.S (conductor should be >25mm (1") from the probe latch). | 
         
        
            | Enclosure material | 
            UL 94-V0 rated | 
         
        
            | Safety | 
            IEC 1010, Category III 600V | 
         
        
            | Power Supply | 
            8V± 1V (supplied from meter) | 
         
        
            | Operating Temperature | 
            0°C to 50°C (32°F to 122°F) | 
         
        
            | Operating Humidity | 
            Less than 80% RH | 
         
        
            | Dimension | 
         
        
            | Circuit box: | 
            105 x 56.5 x 33 mm. (4.1 X 2.2 X 1.3") | 
         
        
            | Flexible probe: | 
            600mm (23.6") (length), 14.5mm 0.57" (diameter) | 
         
        
            | Cable length : | 
            3.4 meters (11.2 feet) | 
         
        
            | DC plug size : | 
            5.5 mm x 2.5 mm DIA. | 
         
        
            | Weight | 
            480 g (1.06 LB) | 
         
    
 
                     
                      
    
        
            | Product Height | 
            5.75 IN | 
         
        
            | Product Length | 
            10.75 IN | 
         
        
            | Product Width | 
            8.25 IN | 
         
        
            | ECCN Number | 
            EAR99 | 
         
        
            | Country of Origin | 
            Taiwan | 
         
        
            | Shipping Height | 
            5.75 IN | 
         
        
            | Shipping Length | 
            10.75 IN | 
         
        
            | Shipping Width | 
            8.25 IN | 
         
    
  
                    
                    
                    
                   
                        
              
		 | 
	 
 
				 
				
				
					
				 
				
				 
				
			 
		 | 
	 
 
    
     
    
								 | 
							 
						 
					 |