Additel ADT221A
Catalog #: ADT221A
Multifunction Temperature Calibrator
- Overview
- Specifications
- Summary
Product Highlights
- Sources and measures mV, mA, ohms, RTDs, thermocouples, frequency, and pulses
- Simulates and measures 13 thermocouples and 11 RTDs to calibrate transmitters
- 24V loop power supply
- Simultaneous dual reading capability
- Automatic switch test
- Supports square root transmitter
- Pulse frequency output for calibration of flow totalizer
- Smartphone-like menu and interface make operation simpler and easier
- Ultra-compact, size 3.9 in. x 7.6 in. x 2.0 in. (100mm x 192mm x 52mm)
- Weight 1.6 lb (0.7 kg)
- One hand operation
- Cold junction equivalent block in calibrator
- A calibrated PRT element with flexible leads is installed in equivalent block for thermocouple cold junction compensation
- This PRT element can be pulled out from calibrator and re-calibrated and corrected at ice point by users
- ISO17025 Accredited Calibration with data
- Up to 30V voltage on any two sockets and up to 1A current on current sockets will not damage calibrator
- Calibrator will return to normal condition as soon as voltage or current is removed
- Rechargeable Li-ion battery for 15 hours uninterrupted use
- Battery life will be reduced when 24V is applied
- Rechargeable battery is replaceable
- Manage information of device under test
- Set up automated calibration procedures
- As-found and As-left functions allow recording and documenting results for quality control
- Download tasks and upload results
- Snapshots allow you to capture and save work
- CVD coefficients of calibrated PRT can be input into calibrator for accurate temperature measurement
- Build-in converters for pressure units, temperature units, temperature vs. resistance (RTDs), and temperature vs. millivolt (thermocouples)
- 3.5 inch TFT color screen
- 3 year Warranty
Each Unit Includes
- 1 - 110V/220V External Power Adapter (9816-X)
- 1 - Chargeable Li-ion Battery (9712)
- 3 - Sets of Test Leads (6 pcs) (9022)
- 1 - Set of Short Circuit Cables (2 pcs) (9020)
- 1 - Manual
- 1 - ISO17025 Accredited Calibration Certificate
| Measurement Accuracy |
| |
Range |
Resolution |
Accuracy |
| Voltage DC |
±75.0000 mV |
0.1μV |
0.01%RD + 3.75 μV |
| ±30.0000 V |
0.1 mV |
0.01%RD + 1.5 mV |
| Current DC |
± 30.0000 mA |
0.1μA |
0.01%RD + 1.5 μA |
| Resistance |
Two-wire |
0 to 400.000 Ω |
1mΩ |
0.02%RD + 0.02 Ω |
| Three-wire |
0 to 400.000 Ω |
1mΩ |
0.02%RD + 0.02 Ω |
| Four-wire |
0 to 400.000 Ω |
1mΩ |
0.01%RD + 0.02 Ω |
| Two-wire |
0 to 4000.00 Ω |
10mΩ |
0.02%RD + 0.2 Ω |
| Three-wire |
0 to 4000.00 Ω |
10mΩ |
0.02%RD + 0.2 Ω |
| Four-wire |
0 to 4000.00 Ω |
10mΩ |
0.01%RD + 0.2 Ω |
| Frequency |
1 to 50000.0 Hz |
0.1Hz |
0.005%RD + 1 Hz |
| Pulse |
0 to 999999 |
1 |
N/A |
| Limit Switch |
For the contact with potential, the voltage within the range 3V to 24V. |
| Source Accuracy |
| Voltage DC |
-10.000 to 75.000mV |
1μV |
0.02%RD + 4.25 μV |
| |
0 to 12.0000 V |
0.1mV |
0.02%RD + 0.6 mV |
| Current DC |
0 to 22.000 mA |
1μA |
0.02%RD + 1.1 μA |
| Resistance |
1 to 400.00 Ω |
10mΩ |
0.02%RD + 0.02 Ω |
| |
1 to 4000.0 Ω |
100mΩ |
0.03%RD + 0.4 Ω |
| Frequency |
0 to 50000.0 Hz |
0.1Hz |
0.005%RD + 1 Hz |
| Pulse |
0 to 999999 |
1 |
N/A |
| DC24V |
N/A |
N/A |
0.5V |
| Thermocouple Measurement and Source Accuracy |
| Measure and Simulate |
Standard |
Temperature Range (oC) |
Accuracy (oC) |
| Measure |
Source |
| S |
IEC 584 |
-50 to 1768 |
-50 to400 |
1 |
1.1 |
| 400 to 1000 |
0.6 |
0.6 |
| 1000 to1768 |
0.7 |
0.8 |
| R |
IEC 584 |
-50 to 1768 |
-50 to 200 |
1.4 |
1.4 |
| 200 to 500 |
0.6 |
0.6 |
| 500 to 1768 |
0.6 |
0.7 |
| B |
IEC 584 |
0 to 1820 |
50 to 450 |
3.8 |
3.8 |
| 450 to 800 |
0.9 |
0.9 |
| 800 to 1820 |
0.6 |
0.7 |
| K |
IEC 584 |
-270 to 1372 |
-250 to -200 |
1 |
1.1 |
| -200 to -100 |
0.4 |
0.5 |
| -100 to 600 |
0.3 |
0.3 |
| 600 to 1372 |
0.4 |
0.5 |
| N |
IEC 584 |
-270 to 1300 |
-250 to -200 |
1.5 |
1.6 |
| -200 to -100 |
0.5 |
0.6 |
| -100 to 1300 |
0.4 |
0.5 |
| E |
IEC 584 |
-270 to 1000 |
-250 to -200 |
0.6 |
0.7 |
| -200 to -100 |
0.3 |
0.3 |
| -100 to 0 |
0.2 |
0.2 |
| 0 to 700 |
0.2 |
0.3 |
| 700 to 1000 |
0.2 |
0.4 |
| J |
IEC 584 |
-270 to 1200 |
-210 to -100 |
0.3 |
0.3 |
| -100 to 1200 |
0.3 |
0.4 |
| T |
IEC 584 |
-270 to 400 |
-250 to -200 |
0.8 |
0.9 |
| -200 to 0 |
0.4 |
0.4 |
| 0 to 400 |
0.2 |
0.2 |
| C |
ASTM E988 |
0 to 2315 |
0 to 1000 |
0.5 |
0.5 |
| 1000 to 1800 |
0.7 |
0.9 |
| 1800 to 2315 |
1 |
1.4 |
| D |
ASTM E988 |
0 to 2320 |
0 to 100 |
0.5 |
0.5 |
| 100 to 1100 |
0.4 |
0.5 |
| 1100 to 2000 |
0.6 |
0.9 |
| 2000 to 2320 |
0.9 |
1.3 |
| G |
ASTM E1751 |
0 to 2315 |
0 to 200 |
2.4 |
2.4 |
| 200 to 400 |
0.5 |
0.5 |
| 400 to 1400 |
0.4 |
0.5 |
| 1400 to 2315 |
0.7 |
1 |
| L |
DIN43710 |
-200 to 900 |
-200 to -100 |
0.2 |
0.3 |
| -100 to 400 |
0.2 |
0.2 |
| 400 to 900 |
0.2 |
0.3 |
| U |
DIN43710 |
-200 to 600 |
-200 to 0 |
0.4 |
0.4 |
| 0 to 600 |
0.2 |
0.3 |
| *Accuracy witd external cold junction; for internal cold junction add 0.1°C (k=2) |
| Measurement Accuracy |
| Measure and Simulate |
Standard |
Temperature Range (°C) |
Accuracy (°C) |
| Measure (2W/3W) |
Measure (4W) |
Source |
| Pt10(385) |
IEC 751 |
-200 to 850 |
-100 to 200 |
0.65 |
0.6 |
0.65 |
| 200 to 600 |
0.82 |
0.72 |
0.82 |
| 600 to 850 |
0.96 |
0.82 |
0.96 |
| Pt100(385) |
IEC 751 |
-200 to 850 |
-100 to 200 |
0.15 |
0.1 |
0.15 |
| 200 to 600 |
0.26 |
0.16 |
0.26 |
| 600 to 850 |
0.34 |
0.2 |
0.34 |
| Pt100(3916) |
JIS 1604 |
-200 to 850 |
-100 to 200 |
0.15 |
0.1 |
0.15 |
| 200 to 600 |
0.26 |
0.16 |
0.26 |
| 600 to 850 |
0.33 |
0.2 |
0.33 |
| Pt100(3926) |
Minco Application Aid #18 |
-200 to 850 |
-100 to 200 |
0.15 |
0.1 |
0.15 |
| 200 to 600 |
0.26 |
0.16 |
0.26 |
| 600 to 850 |
0.33 |
0.2 |
0.33 |
| Pt500(385) |
IEC 751 |
-200 to 850 |
-100 to 200 |
0.2 |
0.16 |
0.36 |
| 200 to 600 |
0.32 |
0.22 |
0.54 |
| 600 to 850 |
0.4 |
0.27 |
0.67 |
| Pt1000(385) |
IEC 751 |
-200 to 850 |
-100 to 200 |
0.1 |
0.05 |
0.25 |
| 200 to 600 |
0.2 |
0.1 |
0.42 |
| 600 to 850 |
0.27 |
0.14 |
0.54 |
| Cu10(427) |
Minco Application Aid #18 |
-100 to 260 |
-100 to 260 |
0.61 |
0.56 |
0.61 |
| Cu50(428) |
GOST 6651-94 |
-50 to 150 |
-50 to 150 |
0.17 |
0.13 |
0.17 |
| Cu100(428) |
GOST 6651-94 |
-50 to 150 |
-50 to 150 |
0.12 |
0.09 |
0.12 |
| Ni120(672) |
Edison curve #7 |
-100 to 260 |
-100 to 260 |
0.07 |
0.05 |
0.07 |
| Ni100(618) |
DIN 43760 |
-100 to 260 |
-100 to 260 |
0.08 |
0.06 |
0.08 |
| Process / Calibration/Multifunction Calibrators Template |
| Type |
Hand Held |
| Measure Voltage |
Yes |
| Loop Voltage Min |
24 V |
| Simulate Loop Voltage |
Yes |
| Loop Voltage Max |
24 V |
| Measure DC Current |
Yes |
| Measure Resistance |
Yes |
| Resistance Measurement Max |
10 M Ohms (10000000 Ohms) |
| Measure Frequency |
Yes |
| Frequency Measurement Max |
50000 Hz |
| Measure RTD |
Yes |
| Measure Thermocouples |
Yes |
| Pressure Modules Available |
Yes |
| Hart Compatible |
Yes |
| FieldBus Compatible |
No |
| Backlighted |
Yes |
| Graphical Screen |
Yes |
| Types RTD/Thermocouples Accepted |
B, C , E, J, K, L, N, PT10 RTD, PT100 RTD, PT1000 RTD, R, S, T, U |
| Warranty |
3 YEARS |
| Safety Approval |
CE |
| Interfaces I/O |
RS-232 |
| Storage |
Internal Memory |
| Product Weight |
1.6 LBS |
| Product Height |
5.00 IN |
| Product Length |
15.00 IN |
| Product Width |
12.00 IN |
| Data Logging |
Yes |
| HTS/Schedule B Number |
9030.32.0000 |
| Calibration Included |
NIST Calibration |
| Power Supply Voltage |
Battery Powered |
| Country of Origin |
China |
| Shipping Height |
5.00 IN |
| Shipping Length |
15.00 IN |
| Shipping Width |
12.00 IN |
|
|
|
|