| Display | 
            LCD size:66.8 X 52.8 mm. with green backlight | 
        
        
            | Test frequency | 
            100Hz, 120Hz, 1KHz, 10 KHz, 100KHz | 
        
        
            | Dissipation factor | 
            0.000 to 1999 | 
        
        
            | Quality factor | 
            0.000 to 1999 | 
        
        
            | θ measurement | 
            ± 90° | 
        
        
            | Sorting tolerance | 
            ± 0.25%, ± 0.5%, ± 1%, ± 2%, ± 5% ± 10%, ± 20%, +80% -20% | 
        
        
            | Calibration | 
            Open/Short calibration | 
        
        
            | Data output | 
            RS232/USB PC computer interface | 
        
        
            | Power off | 
            Auto shut off saves battery life or manual off by push button | 
        
        
            | Operating temperature | 
            0°C to 50°C | 
        
        
            | Operating humidity | 
            Less then 85% R.H | 
        
        
            | Power Supply | 
            006P DC 9V battery * Alkaline or Heavy duty type | 
        
        
            | Power consumption | 
            DC 35 mA approximately | 
        
        
            | Dimension | 
            193 x 88 x 41mm | 
        
        
            | Weight | 
            385 g * meter only | 
        
    
 
    
        
            | Electrical Specifications (23± 5 ° C) | 
        
        
            | DC Resistance | 
        
        
            | Range | 
            Accuracy | 
            Remark | 
        
        
            | 20Ω | 
            ± (0.5%rdg + 5digits) | 
            After calibration | 
        
        
            | 200Ω | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 2kΩ | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 20kΩ | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 200kΩ | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 2MΩ | 
            ± (0.5%rdg + 5digits) | 
            After calibration | 
        
        
            | 20MΩ | 
            ± (1.0%rdg + 5digits) | 
            After calibration | 
        
        
            | 200MΩ | 
            ± (2.0%rdg + 5digits) | 
            After calibration | 
        
    
 
    
        
            | AC Resistance | 
        
        
            | Range | 
            Accuracy | 
            Accuracy | 
            Remark | 
        
        
            |   | 
            100Hz/120Hz | 
            1000Hz | 
              | 
        
        
            | 20Ω | 
            ± (1% + 5digits) | 
            ± (1%rdg + 5digits) | 
            After calibration | 
        
        
            | 200Ω | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 2kΩ | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 20kΩ | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 200kΩ | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 2MΩ | 
            ± (1.0%rdg + 5digits) | 
            ± (1.0%rdg + 5digits) | 
            After calibration | 
        
        
            | 20MΩ | 
            ± (1.0%rdg + 5digits) | 
            ± (2.0%rdg + 5digits) | 
            After calibration | 
        
        
            |   | 
            10kHz | 
            100kHz | 
              | 
        
        
            | 20Ω | 
            ± (1.0%rdg + 5digits) | 
            ± (2.0%rdg + 5digits) | 
            After calibration | 
        
        
            | 200Ω | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 2kΩ | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 20kΩ | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 200kΩ | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 2MΩ | 
            ± (1%rdg + 5digits) | 
            ± (2.0%rdg + 5digits) | 
            After calibration | 
        
        
            | 20MΩ | 
            ± (2.0%rdg + 5digits) | 
            --------------------- | 
            After calibration | 
        
    
* If the impedance is larger than 10kΩ, Rp is shown on the display.
* If the impedance is less than 10kΩ, Rs is shown on the display.
    
        
            | Capacitance (Cp/Cs) : D ≦ 0.1 | 
        
        
            | Range | 
            Accuracy | 
            Accuracy | 
            Remark | 
        
        
            |   | 
            100Hz/120Hz | 
            1000Hz | 
              | 
        
        
            | 20pF | 
            ± (2.0%rdg + 5digits) | 
            ± (1.0%rdg + 5digits) | 
            After calibration | 
        
        
            | 200pF | 
            ± (1.0%rdg + 5digits) | 
            ± (1.0%rdg + 5digits) | 
            After calibration | 
        
        
            | 2000pF | 
            ± (0.8%rdg + 5digits) | 
            ± (0.8%rdg + 5digits) | 
            After calibration | 
        
        
            | 20nF | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 200nF | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 2000nF | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 20uF | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
              | 
        
        
            | 200uF | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg + 5digits) | 
            After calibration | 
        
        
            | 2000uF | 
            ± (1.0%rdg + 5digits) | 
            ± (1.0%rdg + 5digits) | 
            After calibration | 
        
        
            | 20mF | 
            ± (2.0%rdg + 5digits) | 
            --------------------- | 
            After calibration | 
        
        
            |   | 
            10kHz | 
            100kHz | 
              | 
        
        
            | 20pF | 
            ± (1.0%rdg + 5digits) | 
            ± (1.0%rdg + 5digits) | 
            After calibration | 
        
        
            | 200pF | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg+ 5digits) | 
            After calibration | 
        
        
            | 2000pF | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg+ 5digits) | 
            After calibration | 
        
        
            | 20nF | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg+ 5digits) | 
              | 
        
        
            | 200nF | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg+ 5digits) | 
              | 
        
        
            | 2000nF | 
            ± (0.5%rdg + 5digits) | 
            ± (0.5%rdg+ 5digits) | 
              | 
        
        
            | 20uF | 
            ± (0.8%rdg + 5digits) | 
            ± (0.8%rdg+ 5digits) | 
              | 
        
        
            | 200uF | 
            ± (1.0%rdg + 5digits) | 
            --------------------- | 
              | 
        
    
* If the impedance is larger than 10kΩ, Cp is shown on the display.
* If the impedance is less than 10kΩ, Cs is shown on the display.
    
        
            | Inductance (Lp/Ls) : D ≦ 0.1 | 
        
        
            | Range | 
            Accuracy | 
            Accuracy | 
            Remark | 
        
        
            |   | 
            100Hz/120Hz | 
            1000Hz | 
              | 
        
        
            | 20uH | 
            ± (1% + 5d) | 
            ± (1% + 5d) | 
            After calibration | 
        
        
            | 200uH | 
            ± (1% + 5d) | 
            ± (1% + 5d) | 
            After calibration | 
        
        
            | 2000uH | 
            ± (0.8% + 5d) | 
            ± (0.8% + 5d) | 
              | 
        
        
            | 20mH | 
            ± (0.5% + 5d) | 
            ± (0.5% + 5d) | 
              | 
        
        
            | 200mH | 
            ± (0.5% + 5d) | 
            ± (0.5% + 5d) | 
              | 
        
        
            | 2000mH | 
            ± (0.5% + 5d) | 
            ± (0.5% + 5d) | 
              | 
        
        
            | 20H | 
            ± (0.5% + 5d) | 
            ± (0.5% + 5d) | 
              | 
        
        
            | 200H | 
            ± (0.5% + 5d) | 
            ± (0.8% + 5d) | 
            After calibration | 
        
        
            | 2000H | 
            ± (1% + 5d) | 
            --------------------- | 
            After calibration | 
        
        
            |   | 
            10kHz | 
            100khz | 
              | 
        
        
            | 20uH | 
            ± (1% + 5d) | 
            ± (1% + 5d) | 
            After calibration | 
        
        
            | 200uH | 
            ± (0.8% + 5d) | 
            ± (0.8% + 5d) | 
            After calibration | 
        
        
            | 2000uH | 
            ± (0.5% + 5d) | 
            ± (0.5% + 5d) | 
              | 
        
        
            | 20mH | 
            ± (0.5% + 5d) | 
            ± (0.5% + 5d) | 
              | 
        
        
            | 200mH | 
            ± (0.5% + 5d) | 
            --------------------- | 
              | 
        
        
            | 2000mH | 
            ± (0.5% + 5d) | 
            --------------------- | 
              | 
        
    
* If the impedance is larger than 10kΩ, Lp is shown on the display.