AEMC 503
Catalog #: 2117.22
Clamp-on Meter (AC/DC, 400AAC/DC, 600VAC/DC, Ohms, Continuity)
- Overview
- Specifications
- Summary
- Temp. Probes
- Accessories
Product Highlights
- Compact size — fits into your pocket
- 400AAC or 400AAC/DC current measurements
- 600VAC/DC volts measurements
- TRMS measurements (Model 502)
- Resistance measurements to 400?
- Continuity with beeper below 40?
- Frequency measurements (Models 501 and 502) from V and A
- Hold function to “freeze” readings
- Push-button for easy ADC zeroing (Model 503)
- Large, easy-to-read 4000-count display
- 42-segment analog bargraph
- Includes test leads and soft carrying pouch
Applications
- Industrial, commercial, HVAC and residential troubleshooting
- Power panel, junction box and battery bank monitoring
- Electrical testing and troubleshooting on traditional and non-linear loads, such as adjustable speed drives and computers
Each Unit Includes
- 1x Test Leads
- 1x Soft Carrying Pouch
AC Current |
Range |
0.05 to 400A |
Resolution |
40A: 0.01A; 400A: 0.1A |
Basic Accuracy |
50 to 60Hz: ±1.9% of Reading + 5cts; 60 to 500Hz: ±2.5% of Reading + 5cts |
Frequency Range |
50 to 500Hz |
Overload Protection |
600Arms |
DC Amperes |
Range |
0.10 to 400A |
Resolution |
40A: 0.1V; 400A: 0.1A |
Accuracy |
±2.5% of Reading + 10cts |
Overload Protection |
600Arms |
AC Volts |
Input Range |
0.5 to 600V |
Range |
400V / 600V |
Resolution |
0.1V / 1V |
Accuracy |
50 to 60Hz: ±0.8% of Reading + 5cts; 60 to 500Hz: ±1.5% of Reading + 5cts |
Input Impedance |
10MW |
Overload Protection |
600Vrms |
Frequency Current Input |
Frequency Current Input |
Range |
4kHz, 10kHz |
Resolution |
1Hz, 10Hz |
Minimum Input Signal |
2Arms |
Accuracy |
±0.1% of Reading + 1ct |
Input Impedance |
10MW |
Overload Protection |
600Arms |
Frequency Voltage Input |
Range |
4kHz, 40kHz, 400kHz |
Resolution |
1Hz, 10Hz, 100Hz |
Minimum Input Signal |
5Vrms |
Accuracy |
±0.1% of Reading + 1ct |
Input Impedance |
10MW |
Overload Protection |
600Vrms |
DC Volts |
Range |
0.2 to 600V |
Resolution |
400V: 0.1V; 600V: 1V |
Accuracy |
±1% of Reading + 2cts |
Input Impedance |
10MW |
Overload Protection |
600Vrms |
Continuity |
Range |
Beeper |
Measurement |
<40W |
Max. Test Voltage |
1.5VDC |
Overload Protection |
600Vrms |
General Specifications |
Digital Display |
3¾ digits LCD display, 4000 count (max. reading 3999) |
Analog Display |
Fast 42-segment analog bargraph display |
Symbol & Scale Range |
Automatic according to range and input signal |
Polarity |
Minus sign displayed when negative signal applied to input |
Overload |
OL Displayed when input signal exceeds range |
Sample Rate |
2 samples/sec for the digital display; 20 samples/sec for the analog bargraph |
Jaw Opening Size |
1.02" (26mm) |
Battery |
Two 1.5V AAA batteries |
Low Battery Indicator |
Symbol displayed when the battery is below the required voltage |
Auto Power Off |
The meter will power itself OFF if there is no push button or rotary switch operation for 30 minutes |
Dimensions |
7.60 x 1.97 x 1.1" (193 x 50 x 28mm) |
Weight |
8.11oz (230g) with batteries |
Environmental Specification |
Operating Temperature |
32° to 104°F (0° to 40°C), <80% RH, non-condensing |
Storage Temperature |
14° to 140°F (-10° to 60°C), <70% RH, battery removed |
Operating Altitude |
2167 ft (2000m) |
Safety / Reference Specifications |
Safety / Reference Specifications |
Protection Level |
Double insulation; EN 61010-1, 600V, Cat. III, Pollution degree 2 |
Agency Approvals |
CE Mark |
Clamp Meters/Clamp Meters Template |
Type |
Standard Style |
True RMS |
No |
Maximum Current AC |
400 A |
Minimum Current AC |
0.01 A (10 mA) |
Maximum Current DC |
400 A |
Minimum Current DC |
0.01 A (10 mA) |
Maximum Voltage AC |
600 V |
Minimum Voltage AC |
0.5 V (500 mV) |
Maximum Voltage DC |
600 V |
Minimum Voltage DC |
0.2 V (200 mV) |
Basic Voltage Accuracy |
1% of reading ± 2cts |
Digits Display |
3.5 |
Resolution AC Volts |
0.01 V |
Resolution DC Volts |
0.01 V |
Resolution DC Current |
0.1 A |
Maximum Conductor Size |
1.1 IN |
Auto Ranging/Manual |
Auto Ranging |
Auto Power Off |
Yes |
Detachable Jaw |
No |
Rotating Jaw / Swivel |
No |
Peak Hold |
No |
Min/Max |
No |
In-Rush Current |
No |
Dual Display |
No |
Analog Bargraph on Display |
Yes |
Backlight |
Yes |
Remote Display |
No |
Resistance |
No |
Frequency |
No |
Continuity |
Yes |
Capacitance |
No |
Temperature (K T/C) |
No |
Temperature (IR Sensor) |
No |
Diode Testing |
No |
CAT Rating |
III |
CAT Voltage |
300 V |
Overload Protector |
Yes |
True Power (KW) |
No |
Apparent Power (VA) |
No |
Power Factor (PF) |
No |
Single Phase/Three Phase |
Single Phase |
Crest Factor |
No |
Energy (KWh) |
No |
Reactive Power (KVAR) |
No |
Data Logging |
No |
Warranty |
1 YEARS |
Calibration Included |
Factory Calibration |
Power Supply Voltage |
Battery Powered |
Safety Approval |
CE |
Product Weight |
8.11 OUNCES (0.5069 LBS) |
Battery Type |
AAA |
Product Height |
1.0 IN |
Product Length |
7.6 IN |
Product Width |
1.97 IN |
Shipping Weight |
3 LBS |
ECCN Number |
EAR99 |
HTS/Schedule B Number |
9030310000 |
Country of Origin |
Taiwan |
UPC |
685338110029 |
|
Temp. Probes
Accessories
Product |
Price |
|
AEMC 2152.05
Catalog #: 2152.05
Lead - Set of 2, Color-coded (Red/Black) Silicone Leads, Test Probes & Alligator Clips {Rated 1000V CAT IV} (Replacement for Models 401, 403, 405, 407, 601, 603, 605, 607, F05 & F09)
|
$0.00
|
|
AEMC 2154.74
Catalog #: 2154.74
Lead - Replacement Set of 2, Needle Tip Color-coded (Red/Black) w/4mm Right-angle Plug {600V Cat IV w/shield on Needle Tip, 1000V CAT II w/o Sheild} for Models 5212-5217 (or any meter that accepts 4mm banana plugs)
|
$12.21
|
|
|
|