AEMC 503
Catalog #: 2117.22
Clamp-on Meter (AC/DC, 400AAC/DC, 600VAC/DC, Ohms, Continuity)
- Overview
- Specifications
- Summary
- Temp. Probes
- Accessories
Product Highlights
- Compact size — fits into your pocket
- 400AAC or 400AAC/DC current measurements
- 600VAC/DC volts measurements
- TRMS measurements (Model 502)
- Resistance measurements to 400?
- Continuity with beeper below 40?
- Frequency measurements (Models 501 and 502) from V and A
- Hold function to “freeze” readings
- Push-button for easy ADC zeroing (Model 503)
- Large, easy-to-read 4000-count display
- 42-segment analog bargraph
- Includes test leads and soft carrying pouch
Applications
- Industrial, commercial, HVAC and residential troubleshooting
- Power panel, junction box and battery bank monitoring
- Electrical testing and troubleshooting on traditional and non-linear loads, such as adjustable speed drives and computers
Each Unit Includes
- 1x Test Leads
- 1x Soft Carrying Pouch
| AC Current |
| Range |
0.05 to 400A |
| Resolution |
40A: 0.01A; 400A: 0.1A |
| Basic Accuracy |
50 to 60Hz: ±1.9% of Reading + 5cts; 60 to 500Hz: ±2.5% of Reading + 5cts |
| Frequency Range |
50 to 500Hz |
| Overload Protection |
600Arms |
| DC Amperes |
| Range |
0.10 to 400A |
| Resolution |
40A: 0.1V; 400A: 0.1A |
| Accuracy |
±2.5% of Reading + 10cts |
| Overload Protection |
600Arms |
| AC Volts |
| Input Range |
0.5 to 600V |
| Range |
400V / 600V |
| Resolution |
0.1V / 1V |
| Accuracy |
50 to 60Hz: ±0.8% of Reading + 5cts; 60 to 500Hz: ±1.5% of Reading + 5cts |
| Input Impedance |
10MW |
| Overload Protection |
600Vrms |
| Frequency Current Input |
Frequency Current Input |
| Range |
4kHz, 10kHz |
| Resolution |
1Hz, 10Hz |
| Minimum Input Signal |
2Arms |
| Accuracy |
±0.1% of Reading + 1ct |
| Input Impedance |
10MW |
| Overload Protection |
600Arms |
| Frequency Voltage Input |
| Range |
4kHz, 40kHz, 400kHz |
| Resolution |
1Hz, 10Hz, 100Hz |
| Minimum Input Signal |
5Vrms |
| Accuracy |
±0.1% of Reading + 1ct |
| Input Impedance |
10MW |
| Overload Protection |
600Vrms |
| DC Volts |
| Range |
0.2 to 600V |
| Resolution |
400V: 0.1V; 600V: 1V |
| Accuracy |
±1% of Reading + 2cts |
| Input Impedance |
10MW |
| Overload Protection |
600Vrms |
| Continuity |
| Range |
Beeper |
| Measurement |
<40W |
| Max. Test Voltage |
1.5VDC |
| Overload Protection |
600Vrms |
| General Specifications |
| Digital Display |
3¾ digits LCD display, 4000 count (max. reading 3999) |
| Analog Display |
Fast 42-segment analog bargraph display |
| Symbol & Scale Range |
Automatic according to range and input signal |
| Polarity |
Minus sign displayed when negative signal applied to input |
| Overload |
OL Displayed when input signal exceeds range |
| Sample Rate |
2 samples/sec for the digital display; 20 samples/sec for the analog bargraph |
| Jaw Opening Size |
1.02" (26mm) |
| Battery |
Two 1.5V AAA batteries |
| Low Battery Indicator |
Symbol displayed when the battery is below the required voltage |
| Auto Power Off |
The meter will power itself OFF if there is no push button or rotary switch operation for 30 minutes |
| Dimensions |
7.60 x 1.97 x 1.1" (193 x 50 x 28mm) |
| Weight |
8.11oz (230g) with batteries |
| Environmental Specification |
| Operating Temperature |
32° to 104°F (0° to 40°C), <80% RH, non-condensing |
| Storage Temperature |
14° to 140°F (-10° to 60°C), <70% RH, battery removed |
| Operating Altitude |
2167 ft (2000m) |
| Safety / Reference Specifications |
Safety / Reference Specifications |
| Protection Level |
Double insulation; EN 61010-1, 600V, Cat. III, Pollution degree 2 |
| Agency Approvals |
CE Mark |
| Clamp Meters/Clamp Meters Template |
| Type |
Standard Style |
| True RMS |
No |
| Maximum Current AC |
400 A |
| Minimum Current AC |
0.01 A (10 mA) |
| Maximum Current DC |
400 A |
| Minimum Current DC |
0.01 A (10 mA) |
| Maximum Voltage AC |
600 V |
| Minimum Voltage AC |
0.5 V (500 mV) |
| Maximum Voltage DC |
600 V |
| Minimum Voltage DC |
0.2 V (200 mV) |
| Basic Voltage Accuracy |
1% of reading ± 2cts |
| Digits Display |
3.5 |
| Resolution AC Volts |
0.01 V |
| Resolution DC Volts |
0.01 V |
| Resolution DC Current |
0.1 A |
| Maximum Conductor Size |
1.1 IN |
| Auto Ranging/Manual |
Auto Ranging |
| Auto Power Off |
Yes |
| Detachable Jaw |
No |
| Rotating Jaw / Swivel |
No |
| Peak Hold |
No |
| Min/Max |
No |
| In-Rush Current |
No |
| Dual Display |
No |
| Analog Bargraph on Display |
Yes |
| Backlight |
Yes |
| Remote Display |
No |
| Resistance |
No |
| Frequency |
No |
| Continuity |
Yes |
| Capacitance |
No |
| Temperature (K T/C) |
No |
| Temperature (IR Sensor) |
No |
| Diode Testing |
No |
| CAT Rating |
III |
| CAT Voltage |
300 V |
| Overload Protector |
Yes |
| True Power (KW) |
No |
| Apparent Power (VA) |
No |
| Power Factor (PF) |
No |
| Single Phase/Three Phase |
Single Phase |
| Crest Factor |
No |
| Energy (KWh) |
No |
| Reactive Power (KVAR) |
No |
| Data Logging |
No |
| Warranty |
1 YEARS |
| Calibration Included |
Factory Calibration |
| Power Supply Voltage |
Battery Powered |
| Safety Approval |
CE |
| Product Weight |
8.11 OUNCES (0.5069 LBS) |
| Battery Type |
AAA |
| Product Height |
1.0 IN |
| Product Length |
7.6 IN |
| Product Width |
1.97 IN |
| Shipping Weight |
3 LBS |
| ECCN Number |
EAR99 |
| HTS/Schedule B Number |
9030310000 |
| Country of Origin |
Taiwan |
| UPC |
685338110029 |
|
Temp. Probes
Accessories
| Product |
Price |
 |
AEMC 2152.05
Catalog #: 2152.05
Lead - Set of 2, Color-coded (Red/Black) Silicone Leads, Test Probes & Alligator Clips {Rated 1000V CAT IV} (Replacement for Models 401, 403, 405, 407, 601, 603, 605, 607, F05 & F09)
|
$0.00
|
 |
AEMC 2154.74
Catalog #: 2154.74
Lead - Replacement Set of 2, Needle Tip Color-coded (Red/Black) w/4mm Right-angle Plug {600V Cat IV w/shield on Needle Tip, 1000V CAT II w/o Sheild} for Models 5212-5217 (or any meter that accepts 4mm banana plugs)
|
$12.21
|
|
|
|