Fluke 54-2 B 60HZ
Catalog #: 3821070
Dual Input Thermometer with USB Recording, Noise Rejection
- Overview
- Specifications
- Summary
- Temp. Probes
- Accessories
- Cases
Product Highlights
- Data Logging up to 500 points of data with user adjustable recording interval
- Additional thermocouple types R, S, and N (for a total of 7 different types)
- Real time clock captures the exact time of day when events occur
- Recall function allows logged data to be easily reviewed on the meter display
- IR communication port allows data to be exported to optional FlukeView Forms® Temperature PC software for further analysis and graphing
- Relative time clock on MIN, MAX, and AVG provides a time reference for major events
- Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
- Measures J, K, T, and E-types of thermocouples
- Readout in °C, °F, or Kelvin (K)
- Splash and dust resistant case protected by impact absorbing holster
- User-friendly front panel is easy to set up and operate
- Sleep mode increases battery life; typical 1000-hour battery life
- Battery door allows easy battery replacement without breaking the calibration seal
- Optional ToolPak accessory allows the thermometer to hang from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation
- 3 year warranty
Each Unit Includes
General Specifications |
Temperature accuracy |
Above -100°C |
J, K, T, E, and N-type: ±[0.05% + 0.3°C]1 |
R and S-type: ±[0.05% + 0.4°C]1 |
Below -100°C |
J, K, E, and N-types: ±[0.20% + 0.3°C]1 |
T-type: ±[0.50% + 0.3°C] |
Temperature |
J-type |
-210°C to 1200°C |
K-type |
-200°C to 1372°C |
T-type |
-250°C to 400°C |
E-type |
-150°C to 1000°C |
N-type |
-200°C to 1300°C1 |
R and S-type |
0°C to 1767°C1 |
Temperature scale |
ITS-90 |
Applicable standards |
NIST-175 |
Display resolution |
0.1°C, 0.1 K < 1000 |
1°C, 1 K = 1000 |
1. Only the Fluke Models 53 II B and 54 II B thermometers are capable of measuring N, R, and S-type thermocouples. |
Environmental Specifications |
Operating temperature |
-10°C to 50°C |
Storage temperature |
-40°C to 60°C |
Humidity (without condensation) |
0% to 90%; 0°C to 35°C |
0% to 70%; 0°C to 50°C |
Safety Specifications |
Overvoltage category |
CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 |
Agency approvals |
CE, CSA, TÜV (pending) |
Mechanical and General Specifications |
Size (L x W x D) |
173 x 86 x 38 mm |
Weight |
400 g |
Batteries |
3 AA batteries; typical 1000-hour life |
Thermometers/Contact Thermometers Template |
Type (Contact Thermometers) |
Thermocouple |
Types RTD/Thermocouples Accepted |
E, J, K, N, R, S, T |
Number of Probe Inputs/Channels |
2 |
Resolution (thermometers) |
0.1 °C, 0.1 K < 1000
1°C, 1 K >=1000 |
Accuracy |
Above -100 °C: J, K, T, E, and N-type: ±[0.05% + 0.3°C]*
R and S-type: ±[0.05% + 0.4°C]*
Below -100 °C: J, K, E, and N-types: ±[0.20% + 0.3°C]*
T-type: ±[0.50% + 0.3°C] |
Differential Temperature |
Yes |
Food Safe |
No |
Data Logging |
Yes |
Warranty |
3 YEARS |
Power Supply Voltage |
Battery Powered |
Safety Approval |
CSA |
Interfaces I/O |
IR |
Product Weight |
400 GRAMS (0.882 LBS) |
Product Height |
38 MM (1.50 IN) |
Product Length |
173 MM (6.81 IN) |
Product Width |
86 MM (3.39 IN) |
ECCN Number |
EAR99 |
Country of Origin |
China |
|