|
|
|
|
Fluke 772
Catalog #: 3362352
Milliamp Process Calibrator
- Overview
- Specifications
- Summary
- Accessories
Product Highlights
- Best in class 0.2 % accuracy
- 0.01 mA resolution and sensitivity
- Measure 4 to 20 mA signals without ”breaking the loop”
- Measure mA signals for PLC and control system analog I/O
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight illuminates hard to see wires in dark enclosures
- Detachable clamp with extension cable for measurements in tight locations
- Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically change the 4 to 20 mA output for remote testing
- Power saving features, auto-off, backlight timeout extend battery life
- Hold function captures and displays changing measurements
- Measure 4 to 20 mA signals with in-circuit measurement
- Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
- Source 4 to 20 mA signals for testing control system I/O or I/Ps
- mA output linear ramp or 25% step output
- Automatically change the 4 to 20 mA output for remote testing
Each Unit Includes
- Four AA alkaline batteries (installed)
- Soft carrying case
- TL75 test leads
- AC 72 detachable clip
- TL 940 mini hook test leads
- Instruction sheet
- Hanging tool with hook and loop strap
| Specifications |
| Diameter of measurable conductor |
0.177” or 4.5 mm max |
| Operating temperature |
-10 to 50ºC |
| Storage temperature |
-25 to 60ºC |
| Operating humidity |
< 90% @ <30ºC, < 75% @ 30 to 55ºC |
| Operating altitude |
0 to 2000 m |
| IP rating |
IP 40 |
| Size |
44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in) |
| Weight |
410 g, (14.4 oz) |
| Vibration |
Random 2 g, 5 to 500 Hz |
| Shock |
1 meter drop test (except the jaw) |
| EMI/RFI |
Meets EN61326-1 |
| For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m. |
| Temperature coefficient |
0.01% ºC |
| (< 18ºC or > 28ºC) |
| Power, battery life |
(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms |
| Warranty |
Three years for electronics |
| One year for cable and clamp assembly |
| Functional Specifications |
| mA measurement |
Resolution / range |
0 to 20.99 mA |
| (measured by clamp) |
Accuracy |
0.2% + 2 counts |
| |
Resolution / range |
21.0mA to 100.0 mA |
| |
Accuracy |
1% + 5 counts |
| mA measurement (measured in series with test jacks) |
Resolution / range |
0 to 24.00 mA |
| Accuracy |
0.2% + 2 counts |
| mA source (maximum mA drive: 24 mA into 1,000 ohms) |
Resolution / range |
0 to 24.00 mA |
| Accuracy |
0.2% + 2 counts |
| mA simulate (maximum voltage 50 V dc) |
Resolution / range |
0 to 24.00 mA |
| Accuracy |
0.2% + 2 counts |
| Clamp Meters/Clamp Meters Template |
| Type |
Milliamp Process Clamp Meter |
| True RMS |
No |
| Maximum Current DC |
100 mA (0.1 A) |
| Minimum Current DC |
10 mA |
| Basic Voltage Accuracy |
.2% |
| Digits Display |
3.5 |
| Resolution DC Current |
0.01 mA (0.00001 A) |
| Maximum Conductor Size |
0.177 IN |
| Auto Ranging/Manual |
Manual |
| Auto Power Off |
Yes |
| Detachable Jaw |
Yes |
| Rotating Jaw / Swivel |
No |
| Peak Hold |
No |
| Min/Max |
No |
| In-Rush Current |
No |
| Dual Display |
Yes |
| Analog Bargraph on Display |
No |
| Backlight |
Yes |
| Remote Display |
No |
| Resistance |
No |
| Frequency |
No |
| Continuity |
No |
| Capacitance |
No |
| Temperature (K T/C) |
No |
| Temperature (IR Sensor) |
No |
| Diode Testing |
No |
| Overload Protector |
Yes |
| True Power (KW) |
No |
| Apparent Power (VA) |
No |
| Power Factor (PF) |
No |
| Single Phase/Three Phase |
Single Phase |
| Crest Factor |
No |
| Energy (KWh) |
No |
| Reactive Power (KVAR) |
No |
| Source/Simulate (Process Clamp) |
Yes |
| Process / Calibration/Signal Calibrators/Loop Calibrators Template |
| Measure Inputs |
Yes |
| Source Outputs |
Yes |
| Display (Loop Calibrators) |
Dual |
| Maximum Current |
99.9 mA (0.100 A) |
| Current Measurement Resolution |
0.01mA |
| Current Accuracy |
0.2% |
| Measure RTD |
No |
| Measure T/C |
No |
| Measure Resistance |
No |
| Measure Frequency |
No |
| Measure Thermistor |
No |
| Programmable |
No |
| Auto Step/Ramp |
Yes |
| Hart Compatible |
No |
| Battery Life |
12 HR |
| Intrinsically Safe |
No |
| Process / Calibration/Milliamp Calibrators Template |
| Source/Simulate DC Current |
Yes |
| Measure DC Current |
Yes |
| Two Wire Transmitter Simulation |
Yes |
| Percent Display |
Yes |
| Accuracy |
0 to 20.99 mA: 0.2%+2 counts
21.0 mA to 100.0 mA: 1%+5 counts |
| Simulate Loop Voltage |
No |
| Ramp/Step Output |
Yes |
| FieldBus Compatible |
No |
| Data Logging |
No |
| Unique Features |
mA in/out: simultaneously measure the mA signal
with the clamp and source a mA signal
– Apply a mA input signal to a device and measure
its’ 4 to 20 mA output on devices such as valves or mA isolators. |
| Warranty |
3 YEARS |
| Warranty Details |
One-year on mA clamp assembly and cable. |
| Calibration Included |
None |
| Power Supply Voltage |
Battery Powered |
| IP Rating |
IP40 |
| Product Weight |
14.4 OUNCES (0.9 LBS) |
| Product Height |
9.75 IN |
| Product Length |
1.62 IN |
| Product Width |
3 IN |
| ECCN Number |
3A992 |
| HTS/Schedule B Number |
9030.31.0000 |
| Country of Origin |
China |
| CA Residents |
Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov |
|
Accessories
| Product |
Price |
 |
Fluke TL75
Catalog #: 855705
Hard Point Test Lead Set
|
$45.24
|
|
|
|